dc.contributor
Hospital de Figueres, Fundació Salut Empordà, Figueres, Spain.
dc.contributor
Departament de Salut
dc.contributor.author
Pérez Garcia, Isabel
dc.contributor.author
Fernández Punset, Hilda
dc.contributor.author
Reixach Aumatell, Laia
dc.contributor.author
Rey Miguel, Alicia
dc.date.accessioned
2025-10-24T10:50:32Z
dc.date.available
2025-10-24T10:50:32Z
dc.date.issued
2024-07-25T08:53:06Z
dc.date.issued
2024-07-25T08:53:06Z
dc.date.issued
2023-10-27
dc.identifier
Pérez Garcia I, Fernández Punset H, Reixach Aumatell L, Rey Miguel A. Valoració de l'afectació de la paret posterior de la FAVn segons el material de punció. Pòster presentat a: XLVIII Congreso Nacional de la Sociedad Española de Enfermería Nefrológica; 2023 Oct 26-28; Salamanca.
dc.identifier
https://hdl.handle.net/11351/11778
dc.identifier.uri
https://hdl.handle.net/11351/11778
dc.description.abstract
Catéter fístula; Lesión pared posterior; FAVn
dc.description.abstract
Catèter fístula; Lesió paret posterior; FAVn
dc.description.abstract
Catheter fistula; Posterior wall lesion; FAVn
dc.description.abstract
El objetivo de este estudio fue avaluar si el catéter fístula (CF) causa menos daño en la pared posterior del vaso en comparación con la aguja convencional, utilizando ecografías de seguimiento. En un ensayo clínico controlado de 8 meses con 10 pacientes con FAVn radiocefálica con tramo de 4 cm de punción arterial, los resultados mostraron que 40% de los pacientes para quien se ha usado aguja convencional presentaron lesiones, frente al 20% con CF. Las lesiones causadas por la aguja convencional persistieron, mientras que las producidas por el CF desaparecieron. Se confirmó que el CF causa menos lesiones, lo que podría prolongar la vida de las fístulas arteriovenosas y reducir la necesidad de intervenciones quirúrgicas.
dc.description.abstract
L'objectiu d'aquest estudi va ser avaluar si el catèter fístula (CF) causa menys dany a la paret posterior del vas en comparació de l'agulla convencional, utilitzant ecografies de seguiment. En un assaig clínic controlat de 8 mesos amb 10 pacients amb FAVn radiocefàlica amb tram de 4 cm de punció arterial, els resultats van mostrar que 40% dels pacients per a qui s'ha fet servir agulla convencional van presentar lesions, davant del 20% amb CF. Les lesions causades per l'agulla convencional van persistir, mentre que les produïdes pel CF van desaparèixer. Es va confirmar que el CF causa menys lesions, cosa que podria perllongar la vida de les fístules arteriovenoses i reduir la necessitat d'intervencions quirúrgiques.
dc.description.abstract
The aim of this study was to evaluate whether the catheter fistula (CF) causes less damage to the posterior wall of the vessel compared to the conventional needle, using follow-up ultrasounds. In an 8-month controlled clinical trial of 10 patients with radiocephalic AVF with a 4-cm segment of arterial puncture, results showed that 40% of patients for whom a conventional needle was used had lesions, compared to 20% with CF. Lesions caused by the conventional needle persisted, while those produced by the CF disappeared. CF was confirmed to cause fewer lesions, which could prolong the life of arteriovenous fistulas and reduce the need for surgical interventions.
dc.format
application/pdf
dc.relation
XLVIII Congreso Nacional SEDEN
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.subject
Fístules arteriovenoses
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Therapeutics::Therapeutics::Sorption Detoxification::Renal Dialysis
dc.subject
DISEASES::Pathological Conditions, Signs and Symptoms::Pathological Conditions, Anatomical::Fistula::Vascular Fistula::Arteriovenous Fistula
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Equipment and Supplies::Catheters
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::terapéutica::terapéutica::desintoxicación por adsorción::diálisis renal
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::equipos y suministros::catéteres
dc.subject
ENFERMEDADES::enfermedades y anomalías neonatales congénitas y hereditarias::anomalías congénitas::anomalías cardiovasculares::malformaciones vasculares::malformaciones arteriovenosas::fístula arteriovenosa
dc.title
Valoració de l'afectació de la paret posterior de la FAVn segons el material de punció
dc.type
info:eu-repo/semantics/conferenceObject
dc.type
info:eu-repo/semantics/submittedVersion