P09-A130 Management of an eye bank with organ-cultured and hypothermic corneas: microbiology in endothelial grafts

dc.contributor
Institut Català de la Salut
dc.contributor
[Otero Areitio N, Pujagut Mercader N, Vilarrodona Serrat A] Barcelona Tissue Bank, Banc de Sang i Teixits (BST) Barcelona, Spain. Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. [Martinez-Conesa EM, Agustí Rovira E, Fariñas Barbera Ó] Barcelona Tissue Bank, Banc de Sang i Teixits (BST) Barcelona, Spain. Biomedical Research Institute (IIB-Sant Pau; SGR1113), Barcelona, Spain. [Sabater-Cruz N] Hospital Clínic, Barcelona, Spain
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Otero Areitio, Nausica
dc.contributor.author
Martinez-Conesa, Eva Maria
dc.contributor.author
Agustí Rovira, Elba
dc.contributor.author
Pujagut Mercader, Natzaret
dc.contributor.author
Sabater-Cruz, Noelia
dc.contributor.author
Fariñas Barbera, Oscar
dc.contributor.author
Vilarrodona, Anna
dc.date.accessioned
2025-10-24T08:48:32Z
dc.date.available
2025-10-24T08:48:32Z
dc.date.issued
2023-08-31T11:27:13Z
dc.date.issued
2023-08-31T11:27:13Z
dc.date.issued
2023-08-21
dc.identifier
Otero Areitio N, Martinez-Conesa EM, Agustí Rovira E, Pujagut Mercader N, Fariñas Barbera Ó, Sabater-Cruz N, et al. P09-A130 Management of an eye bank with organ-cultured and hypothermic corneas: microbiology in endothelial grafts. BMJ Open Ophthalmol. 2023 Aug 21;8(Suppl 2):A4.2-A5.
dc.identifier
2397-3269
dc.identifier
https://hdl.handle.net/11351/10196
dc.identifier
10.1136/bmjophth-2023-EEBA.9
dc.identifier
37604569
dc.identifier.uri
http://hdl.handle.net/11351/10196
dc.description.abstract
Eye bank; Endothelial grafts
dc.description.abstract
Banco de ojos; Injertos endoteliales
dc.description.abstract
Banc d'ulls; Empelts endotelials
dc.description.abstract
Purpose To analyse the microbiologic control results taken during the processing of hypothermic and cultured corneas for endothelial transplants comparing the two groups from January to September 2022. METHODS The microbiological controls of hypothermic corneas prepared for DSAEK or DMEK are: Transport Eusol control (pre-manipulation) and new Eusol control (post-manipulation). In cultured corneas the number of controls is increased to 4: first culture medium, evaluation culture medium, transport medium 24 hours post-evaluation and transport medium post-manipulation. RESULTS A total of 1438 corneas were processed for transplant during the 9 months studied (321 fresh corneas and 1113 cultured corneas). A total of 557 corneas were prepared for DSAEK or DMEK, from which 89 (15,98%) were hypothermic corneas and 468 (84.O2%) were cultured. From hypothermic corneas, 65 were cut for DSAEK and with 24 corneas, pre-stripping for DMEK was done. In the case of cultured corneas, 187 were cut for DSAEK and with 281 pre-stripping for DMEK was done. The number of corneas with positive results in the microbiological controls were 15 (16,85%) in the case of fresh corneas (in 7 corneas that were prepared for DSAEK and in 8 for DMEK) and 4 cases (0,85%) in cultured corneas (in 3 corneas for DSAEK and in 1 corneas for DMEK) resulting in a clear difference between both preservation methods. Bio-surveillance notifications notified during the studied period have been a total of 5, from which 2 were SAE in hypothermic corneas and other 2 were SAE and 1 SAR, in cultured corneas, all for endothelial transplantations. Conclusion The number of positive results for microorganisms was higher in the case of hypothermic corneas and the Bio-surveillance notifications were also a little bit higher in hypothermic corneas (2,25%) comparing to organ cultured corneas (0.64%). The management of an eye bank with both preservation systems is challenging with its advantages and disadvantages. The main disadvantage of hypothermic corneas is the risk of not detecting contaminations because the corneas are released without any definitive results but it is compensated by the fact that they allow us to respond to emergencies, tissue returns, apart from the economic aspect.
dc.format
application/pdf
dc.language
eng
dc.publisher
BMJ
dc.relation
BMJ Open Ophthalmology;8(suppl 2)
dc.relation
http://dx.doi.org/10.1136/bmjophth-2023-EEBA.9
dc.rights
Attribution-NonCommercial 4.0 International
dc.rights
http://creativecommons.org/licenses/by-nc/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Scientia
dc.subject
Còrnia
dc.subject
Trasplantació d'òrgans, teixits, etc.
dc.subject
Contaminació
dc.subject
Microorganismes
dc.subject
HEALTH SURVEILLANCE::Health Surveillance of Health Services::Health Facilities::Biological Specimen Banks::Eye Banks
dc.subject
HEALTH CARE::Environment and Public Health::Public Health::Drug Contamination
dc.subject
ANATOMY::Sense Organs::Eye::Anterior Eye Segment::Cornea
dc.subject
VIGILANCIA SANITARIA::vigilancia sanitaria de los servicios de salud::centros sanitarios::bancos de muestras biológicas::bancos de ojos
dc.subject
ATENCIÓN DE SALUD::ambiente y salud pública::salud pública::contaminación de medicamentos
dc.subject
ANATOMÍA::órganos de los sentidos::ojo::segmento anterior del ojo::córnea
dc.title
P09-A130 Management of an eye bank with organ-cultured and hypothermic corneas: microbiology in endothelial grafts
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)