Avaluació del cabal per SPE amb òxid de titani com a adsorbent per a la preconcentració i determinació de Glifosat i àcid aminometilfosfònic en matrius aquoses

dc.contributor
Universitat de Girona. Facultat de Ciències
dc.contributor
Sanchez Navarro, Juan Manuel
dc.contributor.author
Cañigueral Sanclement, Joan
dc.date.accessioned
2026-03-24T23:53:36Z
dc.date.available
2026-03-24T23:53:36Z
dc.date.issued
2025-07
dc.identifier
http://hdl.handle.net/10256/28516
dc.identifier.uri
https://hdl.handle.net/10256/28516
dc.description.abstract
Glyphosate (GLP) is a herbicide that is widely used today. This compound and its main degradation product, aminomethylphosphonic acid (AMPA), are environmentally controversial due to their persistence and possible toxicity. Their presence is mainly found in transgenic crops. In the European context, due to the lack of results conclusively demonstrating the carcinogenic effect of GLP, the European Commission renewed its authorization for use until 2033. The aim of this work is to evaluate the use of titanium dioxide (TiO₂) as an adsorbent using the solid-phase extraction (SPE) methodology for the detection of Glyphosate and its metabolite AMPA in natural waters. The study is mainly focused on the effect of the loading flow rate on adsorption. SPE with titanium dioxide takes advantage of the high affinity of this oxide for phosphorous compounds, making it a useful tool for concentrating analytes in samples containing interfering substances, such as natural waters. For the analysis, it is necessary to carry out the derivatization of the analytes with a commercial derivatizing reagent (AccQ-Fluor™) to obtain fluorescent compounds that can be detected by HPLC with a fluorescence detector. This significantly improves selectivity and sensitivity compared to UV detection. Calibration curves have been prepared in the range of 1– 60 mg/L, showing linearity. Heteroscedasticity is observed in the responses, so a weighted least squares (WLS) regression is required to improve the precision and accuracy of the results. In the flow studies, it was found that flow rates <1 mL/min are necessary to achieve quantitative adsorption and recoveries close to 100%. At higher flow rates, analyte retention decreases significantly. Various samples of natural waters have been analyzed. Except in one case, a sample from the mining area of the Osar River, neither Glyphosate nor AMPA was detected. Therefore, the SPE technique using TiO₂ as an adsorbent is promising for detecting both GLP and its metabolite AMPA, although it would be necessary to increase the sample volume or use more sensitive detectors, such as mass spectrometry, to achieve lower detection limits
dc.description.abstract
6
dc.format
application/pdf
dc.language
cat
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Química (TFG)
dc.subject
Glifosat
dc.subject
Diòxid de titani
dc.subject
Aminomethylphosphonic acid
dc.subject
Glyphosate
dc.subject
Titanium dioxide
dc.subject
Àcid aminometilfosfònic
dc.title
Avaluació del cabal per SPE amb òxid de titani com a adsorbent per a la preconcentració i determinació de Glifosat i àcid aminometilfosfònic en matrius aquoses
dc.type
info:eu-repo/semantics/bachelorThesis


Files in this item

FilesSizeFormatView

There are no files associated with this item.