dc.description.abstract
The popularity of continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, as a way to deliver insulin more physiologically and achieve better glycemic control in diabetes patients has increased. Despite the substantiated therapeutic advantages of using CSII, its use has also been associated with an increased risk of technical malfunctioning of the device, which leads to an increased risk of acute metabolic complications, such as diabetic ketoacidosis. Current insulin pumps already incorporate systems to detect some types of faults, such as obstructions in the infusion set, but are not able to detect other types of fault such as the disconnection or leakage of the infusion set
dc.description.abstract
This work has been funded by the Wellcome Trust, the Spanish Ministry of Science and Innovation through grant DPI2010-20764-C02, the European Union through FEDER funds and Generalitat de Catalunya under grant 2009 SGR 523
dc.format
11 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Diabetes Technology Society
dc.relation
info:eu-repo/semantics/altIdentifier/doi/10.1177/193229681200600518
dc.relation
info:eu-repo/semantics/altIdentifier/issn/1932-2968
dc.relation
DPI2010-20764-C02-02
dc.relation
info:eu-repo/grantAgreement/MICINN//DPI2010-20764-C02-02/ES/NUEVAS ESTRATEGIAS DE CONTROL GLUCEMICO POSTPRANDIAL MEDIANTE TERAPIA CON BOMBA DE INSULINA EN DIABETES TIPO 1/
dc.rights
Tots els drets reservats
dc.rights
info:eu-repo/semantics/openAccess
dc.source
© Journal of Diabetes Science and Technology, 2012, vol. 6, núm. 5, p. 1131-1141
dc.source
Articles publicats (D-EEEiA)
dc.source
Herrero i Viñas, Pau Calm i Puig, Remei Vehí, Josep Armengol Llobet, Joaquim Georgiou, Pantelis Oliver, Nick Toumazou, Christofer 2012 Robust Fault Detection System for Insulin Pump Therapy Using Continuous Glucose Monitoring Journal of Diabetes Science and Technology 6 5 1131 1141
dc.subject
Medicaments -- Modes d'administració
dc.subject
Drug delivery systems
dc.subject
Insulina -- Administració
dc.subject
Insuline -- Administration
dc.subject
Diabetis -- Tractament
dc.subject
Diabetes -- Treatment
dc.subject
Control automàtic
dc.title
Robust Fault Detection System for Insulin Pump Therapy Using Continuous Glucose Monitoring
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion
dc.type
peer-reviewed


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)