Intermittent closed-loop blood glucose control for people with type 1 diabetes on multiple daily injections

dc.contributor
Agencia Estatal de Investigación
dc.contributor.author
Estremera, Ernesto
dc.contributor.author
Beneyto Tantiña, Aleix
dc.contributor.author
Cabrera, Alvis
dc.contributor.author
Contreras, Ivan
dc.contributor.author
Vehí, Josep
dc.date.accessioned
2024-06-18T14:39:20Z
dc.date.available
2024-06-18T14:39:20Z
dc.date.issued
2023-06
dc.identifier
http://hdl.handle.net/10256/22984
dc.identifier.uri
http://hdl.handle.net/10256/22984
dc.description.abstract
Background and objectives: Recent advances in Automated Insulin Delivery systems have been shown to dramatically improve glycaemic control and reduce the risk of hypoglycemia in people with type 1 diabetes. However, they are complex systems that require specific training and are not affordable for most. Attempts to reduce the gap with closed-loop therapies using advanced dosing advisors have so far failed, mainly because they require too much human intervention. With the advent of smart insulin pens, one of the main constraints (having reliable bolus and meal information) disappears and new strategies can be employed. This is our starting hypothesis, which we have validated in a very demanding simulator. In this paper, we propose an intermittent closed-loop control system specifically intended for multiple daily injection therapy to bring the benefits of artificial pancreas to the application of multiple daily injections. Methods: The proposed control algorithm is based on model predictive control and integrates two patient-driven control actions. Correction insulin boluses are automatically computed and recommended to the patient to minimize the duration of hyperglycemia. Rescue carbohydrates are also triggered to avoid hypoglycemia episodes. The algorithm can adapt to different patient lifestyles with customizable triggering conditions, closing the gap between practicality and performance. The proposed algorithm is compared with conventional open-loop therapy, and its superiority is demonstrated through extensive in silico evaluations using realistic cohorts and scenarios. The evaluations were conducted in a cohort of 47 virtual patients. We also provide detailed explanations of the implementation, imposed constraints, triggering conditions, cost functions, and penalties for the algorithm. Results: The in-silico outcomes combining the proposed closed-loop strategy with slow-acting insulin analog injections at 09:00 h resulted in percentages of time in range (TIR) (70–180 mg/dL) of 69.5%, 70.6%, and 70.4% for glargine-100, glargine-300, and degludec-100, respectively, and injections at 20:00 h resulted in percentages of TIR of 70.5%, 70.3%, and 71.6%, respectively. In all the cases, the percentages of TIR were considerably higher than those obtained from the open-loop strategy, being only 50.7%, 53.9%, and 52.2% for daytime injection and 55.5%, 54.1%, and 56.9% for nighttime injection. Overall, the occurrence of hypoglycemia and hyperglycemia was notably reduced using our approach. Conclusions: Event-triggering model predictive control in the proposed algorithm is feasible and may meet clinical targets for people with type 1 diabetes
dc.description.abstract
This work was partially supported by the Spanish Ministry of Science and Innovation under Grant number PID2019-107722RB-C22, by the Autonomous Government of Catalonia under Grant number 2017 SGR 1551, by the Spanish Ministry of Universities and European Union through the Next GenerationEU Plan (Margarita Salas), and by the program for researchers in training at the University of Girona (IFUdG2019)
dc.description.abstract
Open Access funding provided thanks to the CRUE-CSIC agreement with Elsevier
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier
dc.relation
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.cmpb.2023.107568
dc.relation
info:eu-repo/semantics/altIdentifier/issn/0169-2607
dc.relation
info:eu-repo/semantics/altIdentifier/eissn/1872-7565
dc.relation
PID2019-107722RB-C22
dc.relation
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2019-107722RB-C22/ES/PATIENT-TAILORED SOLUTIONS FOR BLOOD GLUCOSE CONTROL IN TYPE 1 DIABETES/
dc.rights
Attribution 4.0 International
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Computer Methods and Programs in Biomedicine, 2023, vol. 236, art. núm. 107568
dc.source
Articles publicats (D-EEEiA)
dc.subject
Diabetis
dc.subject
Diabetes
dc.subject
Glucèmia -- Control automàtic
dc.subject
Blood sugar -- Automatic control
dc.subject
Control predictiu
dc.subject
Predictive control
dc.title
Intermittent closed-loop blood glucose control for people with type 1 diabetes on multiple daily injections
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion
dc.type
peer-reviewed


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)