Intra- and Inter-Rater Reliability of the Modified Tuck Jump Assessment

dc.contributor.author
Fort-Vanmeerhaeghe, Azahara
dc.contributor.author
Montalvo, Alicia M.
dc.contributor.author
Lloyd, Rhodri S.
dc.contributor.author
Read, Paul
dc.contributor.author
Myer, Gregory D.
dc.date.accessioned
2024-06-14T10:20:36Z
dc.date.available
2024-06-14T10:20:36Z
dc.date.issued
2017-03-01
dc.identifier
http://hdl.handle.net/10256/17000
dc.identifier.uri
https://hdl.handle.net/10256/17000
dc.description.abstract
The Tuck Jump Assessment (TJA) is a clinician-friendly screen-ing tool that was designed to support practitioners with identifi-cation of neuromuscular deficits associated with anterior cruci-ate ligament injury. This study aimed to evaluate the inter- and intra-rater reliability of the modified scoring (0 to 2) TJA to add an additional range of objectivity for each criterion. A total of 24 elite youth volleyball athletes (12 males and 12 females) were included in this study. Each participant’s recorded perfor-mance of the TJA was scored independently by two raters across ten criteria using the modified scale. The two raters then scored the same videos one week later. Another investigator who was blind to the identity of the raters analyzed the scores from both raters for each participant. Kappa coefficient (k) and percentage of exact agreement (PEA) for both intra- and inter-rater reliabil-ity were analyzed for each item. Intraclass correlation coeffi-cients (ICC) were calculated to determine intra- and inter-rater reliability of the modified TJA total score. Intra- and inter-rater k was good to excellent for most items (0.65-0.91). Average PEA between the two raters and two sessions ranged from 83.3 to 100% in all scored items. The ICC for the total score was excellent in both inter- and inter-rater correlations (0.94-0.96). This research demonstrated that the modified version of the TJA predominantly shows good to excellent intra- and inter-rater reliability in all analyzed criteria
dc.format
application/pdf
dc.language
eng
dc.publisher
University of Uludag
dc.relation
info:eu-repo/semantics/altIdentifier/issn/1303-2968
dc.rights
Tots els drets reservats
dc.rights
info:eu-repo/semantics/openAccess
dc.source
© Journal of Sports Science and Medicine, 2017, vol. 16, p. 117-124
dc.source
Articles publicats (EUSES)
dc.subject
Mesurament -- Instruments
dc.subject
Measuring instruments
dc.subject
Malalties neuromusculars
dc.subject
Neuromuscular diseases
dc.title
Intra- and Inter-Rater Reliability of the Modified Tuck Jump Assessment
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion
dc.type
peer-reviewed


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)