In vivo pulsed-field ablation in healthy vs. chronically infarcted ventricular myocardium: biophysical and histologic characterization

dc.contributor.author
Sandhu, Uday
dc.contributor.author
Alkukhun, Laith
dc.contributor.author
Kheiri, Babikir
dc.contributor.author
Hodovan, James
dc.contributor.author
Chiang, Kirby
dc.contributor.author
Splanger, Taylor
dc.contributor.author
Castellví Fernández, Quim
dc.contributor.author
Zhao, Yan
dc.contributor.author
Nazer, Babak
dc.date.accessioned
2026-02-24T07:42:43Z
dc.date.available
2026-02-24T07:42:43Z
dc.date.issued
2026-02-23T09:51:45Z
dc.date.issued
2026-02-23T09:51:45Z
dc.date.issued
2023
dc.date.issued
2026-02-23T09:51:45Z
dc.identifier
Sandhu U, Alkukhun L, Kheiri B, Hodovan J, Chiang K, Splanger T, Castellví Fernández Q, Zhao Y, Nazer B. In vivo pulsed-field ablation in healthy vs. chronically infarcted ventricular myocardium: biophysical and histologic characterization. Europace. 2023;25(4):1503-9. DOI: 10.1093/europace/euac252
dc.identifier
1099-5129
dc.identifier
https://hdl.handle.net/10230/72640
dc.identifier
http://dx.doi.org/10.1093/europace/euac252
dc.identifier.uri
https://hdl.handle.net/10230/72640
dc.description.abstract
Aims Data on ventricular pulsed-field ablation (PFA) are sparse in the setting of chronic myocardial infarction (MI). The objective of this study was to compare the biophysical and histopathologic characteristics of PFA in healthy and MI swine ventricular myocardium. Methods and results Myocardial infarction swine (n = 8) underwent coronary balloon occlusion and survived for 30 days. We then performed endocardial unipolar, biphasic PFA of the MI border zone and a dense scar with electroanatomic mapping and using an irrigated contact force (CF)-sensing catheter with the CENTAURI System (Galaxy Medical). Lesion and biophysical characteristics were compared with three controls: MI swine undergoing thermal ablation, MI swine undergoing no ablation, and healthy swine undergoing similar PFA applications that included linear lesion sets. Tissues were systematically assessed by gross pathology utilizing 2,3,5-triphenyl-2H-tetrazolium chloride staining and histologically with haematoxylin and eosin and trichrome. Pulsed-field ablation in healthy myocardium generated well-demarcated ellipsoid lesions (7.2 ± 2.1 mm depth) with contraction band necrosis and myocytolysis. Pulsed-field ablation in MI demonstrated slightly smaller lesions (depth 5.3 ± 1.9 mm, P = 0.0002), and lesions infiltrated into the irregular scar border, resulting in contraction band necrosis and myocytolysis of surviving myocytes and extending to the epicardial border of the scar. Coagulative necrosis was present in 75% of thermal ablation controls but only in 16% of PFA lesions. Linear PFA resulted in contiguous linear lesions with no gaps in gross pathology. Neither CF nor local R-wave amplitude reduction correlated with lesion size. Conclusion Pulsed-field ablation of a heterogeneous chronic MI scar effectively ablates surviving myocytes within and beyond the scar, demonstrating promise for the clinical ablation of scar-mediated ventricular arrhythmias.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
Oxford University Press
dc.relation
Europace. 2023;25(4):1503-9
dc.rights
© The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
dc.rights
https://creativecommons.org/licenses/by-nc/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.subject
Ventricular tachycardia
dc.subject
Ventricular arrhythmia
dc.subject
Pulsed-field ablation
dc.subject
Catheter ablation
dc.title
In vivo pulsed-field ablation in healthy vs. chronically infarcted ventricular myocardium: biophysical and histologic characterization
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)