Modelling the cooling of concrete by piped water
Myers, T. G.
Fowkes, N. D.
Ballim, Y.
Centre de Recerca Matemàtica

Publicació: Centre de Recerca Matemàtica 2010
Descripció: 22 p.
Resum: Piped water is used to remove hydration heat from concrete blocks during construction. In this paper we develop an approximate model for this process. The problem reduces to solving a one-dimensional heat equation in the concrete, coupled with a first order differential equation for the water temperature. Numerical results are presented and the effect of varying model parameters shown. An analytical solution is also provided for a steady-state constant heat generationmodel. This helps highlight the dependence on certain parameters and can therefore provide an aid in the design of cooling systems.
Drets: Aquest document està subjecte a una llicència d'ús de Creative Commons, amb la qual es permet copiar, distribuir i comunicar públicament l'obra sempre que se'n citin l'autor original, la universitat i el centre i no se'n faci cap ús comercial ni obra derivada, tal com queda estipulat en la llicència d'ús Creative Commons
Llengua: Anglès
Col·lecció: Centre de Recerca Matemàtica. Prepublicacions
Col·lecció: Prepublicacions del Centre de Recerca Matemàtica ; 921
Document: Article ; Prepublicació ; Versió de l'autor
Matèria: Temperatura ; Models matemàtics ; Anàlisi tèrmica



22 p, 207.0 KB

El registre apareix a les col·leccions:
Documents de recerca > Prepublicacions

 Registre creat el 2010-09-07, darrera modificació el 2023-02-11



   Favorit i Compartir