<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-17T23:46:07Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2445/98051" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2445/98051</identifier><datestamp>2025-12-04T19:38:22Z</datestamp><setSpec>com_2072_1057</setSpec><setSpec>col_2072_478813</setSpec><setSpec>col_2072_478917</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Análisis of Benzalkonium chloride by capillary electrophoresis-electrospray-Tandem mass spectrometry</dc:title>
   <dc:creator>Para, B. V. (Bianca Veronica)</dc:creator>
   <dc:creator>Núñez Burcio, Oscar</dc:creator>
   <dc:creator>Moyano Morcillo, Encarnación</dc:creator>
   <dc:creator>Galcerán Huguet, M. Teresa</dc:creator>
   <dc:subject>Electroforesi capil·lar</dc:subject>
   <dc:subject>Capillary electrophoresis</dc:subject>
   <dcterms:abstract>Conditions for the separation and determination of benzalkonium chloride (BAC) homologues by CE with UV-detection and CE coupled to MS (IT) using electrospray as ionization source were established. The separation was performed using fused-silica capillaries of 50 μm id and 100 mM acetic acid-ammonium acetate buffer solution at pH 4.5 with 80% of ACN as carrier electrolyte. CE-MS coupling parameters were optimized and methanol-10 mM acetic acid (90:10 v/v) was selected as sheath liquid. Detection limits, based on an S/N of 3:1, were calculated, and values between 0.8 and 1.3 mg/L with CE-ESI/MS and around 0.5 mg/L with CE-ESI-MS/MS, using hydrodynamic injection (15 s, 3.5 kPa), were obtained. Good run-to-run and day-to-day precisions on concentration were achieved with RSDs lower than 8%. Quantitative analysis was carried out by the internal standard method and the calibration curves showed good linearities (r2>0.98). The CE-ESI-MS/MS method was successfully applied to the analysis of BAC in different ophthalmic solutions, allowing the direct determination, identification and confirmation of the BAC homologues presented in these samples.</dcterms:abstract>
   <dcterms:issued>2016-04-29T11:18:30Z</dcterms:issued>
   <dcterms:issued>2016-04-29T11:18:30Z</dcterms:issued>
   <dcterms:issued>2006-05-30</dcterms:issued>
   <dcterms:issued>2016-04-29T11:18:36Z</dcterms:issued>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:type>info:eu-repo/semantics/acceptedVersion</dc:type>
   <dc:relation>Versió postprint del document publicat a: http://dx.doi.org/10.1002/elps.200500716</dc:relation>
   <dc:relation>Electrophoresis, 2006, vol. 27, num. 11, p. 2225-2232</dc:relation>
   <dc:relation>http://dx.doi.org/10.1002/elps.200500716</dc:relation>
   <dc:rights>(c) Wiley-VCH, 2006</dc:rights>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:publisher>Wiley-VCH</dc:publisher>
   <dc:source>Articles publicats en revistes  (Enginyeria Química i Química Analítica)</dc:source>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>