<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-19T12:05:07Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2445/228744" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2445/228744</identifier><datestamp>2026-04-10T05:04:54Z</datestamp><setSpec>com_2072_1057</setSpec><setSpec>col_2072_478861</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Nurse-led Management of Atrial Fibrillation in Patients With Implanted Cardiac Devices</dc:title>
   <dc:creator>Cano-Valls, Alba</dc:creator>
   <dc:creator>Martínez Momblán, Ma. Antonia</dc:creator>
   <dc:creator>Domingo Criado, Rebeca</dc:creator>
   <dc:creator>Niebla Bellido, Mireia</dc:creator>
   <dc:creator>Venturas Nieto, Montserrat</dc:creator>
   <dc:creator>Roca Luque, Ivo</dc:creator>
   <dc:creator>Tolosana, José M. (José María)</dc:creator>
   <dc:creator>Mont Girbau, Lluís</dc:creator>
   <dc:creator>Guasch i Casany, Eduard</dc:creator>
   <dc:subject>Fibril·lació auricular</dc:subject>
   <dc:subject>Desfibril·ladors cardioversors implantables</dc:subject>
   <dc:subject>Fibril·lació ventricular</dc:subject>
   <dc:subject>Atrial fibrillation</dc:subject>
   <dc:subject>Implantable cardioverter-defibrillators</dc:subject>
   <dc:subject>Ventricular fibrillation</dc:subject>
   <dcterms:abstract>This report describes the management of atrial fibrillation (AFib) events diagnosed through cardiac implantedelectronic devices in an advanced nurse practitioner-led clinic. AFib events necessitating medical evaluationwere managed with a standardized decision tree and recorded for 1 year. Among 1980 follow-up assessments, 6% experienced AFib events (n ¼ 119), mostly because of de novo AFib (58%), rapid ventricular rate (22%), and symptomatic AFib (20%). Only 11% were referred to the emergency department, and 83% were assessed by the general practitioner in the same month. Advanced nurse practitioners offer prompt AFib event management in patients with cardiac implanted electronic devices, supported by a structured care pathway ensuring timely medical assessment and treatment.</dcterms:abstract>
   <dcterms:dateAccepted>2026-04-10T05:04:54Z</dcterms:dateAccepted>
   <dcterms:available>2026-04-10T05:04:54Z</dcterms:available>
   <dcterms:created>2026-04-10T05:04:54Z</dcterms:created>
   <dcterms:issued>2026-04-09T09:58:21Z</dcterms:issued>
   <dcterms:issued>2026-04-09T09:58:21Z</dcterms:issued>
   <dcterms:issued>2025-04</dcterms:issued>
   <dcterms:issued>2026-04-09T09:58:21Z</dcterms:issued>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
   <dc:identifier>https://hdl.handle.net/2445/228744</dc:identifier>
   <dc:relation>Reproducció del document publicat a: https://doi.org/10.1016/j.nurpra.2025.105362</dc:relation>
   <dc:relation>The Journal for Nurse Practitioners, 2025, vol. 21, num.4</dc:relation>
   <dc:relation>https://doi.org/10.1016/j.nurpra.2025.105362</dc:relation>
   <dc:rights>cc-by (c) Cano-Valls, Alba et al., 2025</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:publisher>Elsevier Inc.</dc:publisher>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>