<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-19T13:36:51Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2445/228744" metadataPrefix="oai_dc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2445/228744</identifier><datestamp>2026-04-10T05:04:54Z</datestamp><setSpec>com_2072_1057</setSpec><setSpec>col_2072_478861</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Nurse-led Management of Atrial Fibrillation in Patients With Implanted Cardiac Devices</dc:title>
   <dc:creator>Cano-Valls, Alba</dc:creator>
   <dc:creator>Martínez Momblán, Ma. Antonia</dc:creator>
   <dc:creator>Domingo Criado, Rebeca</dc:creator>
   <dc:creator>Niebla Bellido, Mireia</dc:creator>
   <dc:creator>Venturas Nieto, Montserrat</dc:creator>
   <dc:creator>Roca Luque, Ivo</dc:creator>
   <dc:creator>Tolosana, José M. (José María)</dc:creator>
   <dc:creator>Mont Girbau, Lluís</dc:creator>
   <dc:creator>Guasch i Casany, Eduard</dc:creator>
   <dc:subject>Fibril·lació auricular</dc:subject>
   <dc:subject>Desfibril·ladors cardioversors implantables</dc:subject>
   <dc:subject>Fibril·lació ventricular</dc:subject>
   <dc:subject>Atrial fibrillation</dc:subject>
   <dc:subject>Implantable cardioverter-defibrillators</dc:subject>
   <dc:subject>Ventricular fibrillation</dc:subject>
   <dc:description>This report describes the management of atrial fibrillation (AFib) events diagnosed through cardiac implantedelectronic devices in an advanced nurse practitioner-led clinic. AFib events necessitating medical evaluationwere managed with a standardized decision tree and recorded for 1 year. Among 1980 follow-up assessments, 6% experienced AFib events (n ¼ 119), mostly because of de novo AFib (58%), rapid ventricular rate (22%), and symptomatic AFib (20%). Only 11% were referred to the emergency department, and 83% were assessed by the general practitioner in the same month. Advanced nurse practitioners offer prompt AFib event management in patients with cardiac implanted electronic devices, supported by a structured care pathway ensuring timely medical assessment and treatment.</dc:description>
   <dc:date>2026-04-09T09:58:21Z</dc:date>
   <dc:date>2026-04-09T09:58:21Z</dc:date>
   <dc:date>2025-04</dc:date>
   <dc:date>2026-04-09T09:58:21Z</dc:date>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
   <dc:identifier>1555-4155</dc:identifier>
   <dc:identifier>https://hdl.handle.net/2445/228744</dc:identifier>
   <dc:identifier>763373</dc:identifier>
   <dc:identifier>https://hdl.handle.net/2445/228744</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:relation>Reproducció del document publicat a: https://doi.org/10.1016/j.nurpra.2025.105362</dc:relation>
   <dc:relation>The Journal for Nurse Practitioners, 2025, vol. 21, num.4</dc:relation>
   <dc:relation>https://doi.org/10.1016/j.nurpra.2025.105362</dc:relation>
   <dc:rights>cc-by (c) Cano-Valls, Alba et al., 2025</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:format>9 p.</dc:format>
   <dc:format>application/pdf</dc:format>
   <dc:publisher>Elsevier Inc.</dc:publisher>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>