<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-13T07:33:54Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2445/139347" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2445/139347</identifier><datestamp>2025-12-04T19:36:35Z</datestamp><setSpec>com_2072_1057</setSpec><setSpec>col_2072_478813</setSpec><setSpec>col_2072_478917</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Ex-situ antimony screen-printed carbon electrode for voltammetric determination of Ni(II) - ions in wastewater</dc:title>
   <dc:creator>Barceló, Cristian</dc:creator>
   <dc:creator>Serrano i Plana, Núria</dc:creator>
   <dc:creator>Ariño Blasco, Cristina</dc:creator>
   <dc:creator>Díaz Cruz, José Manuel</dc:creator>
   <dc:creator>Esteban i Cortada, Miquel</dc:creator>
   <dc:subject>Níquel</dc:subject>
   <dc:subject>Voltametria</dc:subject>
   <dc:subject>Anàlisi electroquímica</dc:subject>
   <dc:subject>Nickel</dc:subject>
   <dc:subject>Voltammetry</dc:subject>
   <dc:subject>Electrochemical analysis</dc:subject>
   <dcterms:abstract>An Ex-situ antimony film screen-printed carbon electrode (Ex-situ SbSPCE) was successfully applied for the determination of Ni(II), by means of adsorptive stripping voltammetry using dimethylglyoxime as complexing agent, in a certified reference wastewater sample. This electrode is proposed as an alternative to more conventional antimony film electrodes. Ex-situ SbSPCE was analytically characterized and the obtained parameters suggest that Ex-situ SbSPCE behaves much better than both Ex-situ BiSPCE and BispSPE for Ni(II) determination. The results confirm the applicability of Ex-situ SbSPCE for the determination of low concentration levels of Ni(II) in natural samples with a very high reproducibility and good trueness.</dcterms:abstract>
   <dcterms:issued>2019-09-05T12:06:19Z</dcterms:issued>
   <dcterms:issued>2019-09-05T12:06:19Z</dcterms:issued>
   <dcterms:issued>2015-10-28</dcterms:issued>
   <dcterms:issued>2019-09-05T12:06:20Z</dcterms:issued>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:type>info:eu-repo/semantics/acceptedVersion</dc:type>
   <dc:relation>Versió postprint del document publicat a: https://doi.org/10.1002/elan.201500511</dc:relation>
   <dc:relation>Electroanalysis, 2015, vol. 28, num. 3, p. 640-644</dc:relation>
   <dc:relation>https://doi.org/10.1002/elan.201500511</dc:relation>
   <dc:rights>(c) Wiley-VCH, 2015</dc:rights>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:publisher>Wiley-VCH</dc:publisher>
   <dc:source>Articles publicats en revistes  (Enginyeria Química i Química Analítica)</dc:source>