<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-17T05:20:06Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2445/139347" metadataPrefix="mets">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2445/139347</identifier><datestamp>2025-12-04T19:36:35Z</datestamp><setSpec>com_2072_1057</setSpec><setSpec>col_2072_478813</setSpec><setSpec>col_2072_478917</setSpec></header><metadata><mets xmlns="http://www.loc.gov/METS/" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" ID="&#xa;&#x9;&#x9;&#x9;&#x9;DSpace_ITEM_2445-139347" TYPE="DSpace ITEM" PROFILE="DSpace METS SIP Profile 1.0" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd" OBJID="&#xa;&#x9;&#x9;&#x9;&#x9;hdl:2445/139347">
   <metsHdr CREATEDATE="2026-04-17T07:20:06Z">
      <agent ROLE="CUSTODIAN" TYPE="ORGANIZATION">
         <name>RECERCAT</name>
      </agent>
   </metsHdr>
   <dmdSec ID="DMD_2445_139347">
      <mdWrap MDTYPE="MODS">
         <xmlData xmlns:mods="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
            <mods:mods xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Barceló, Cristian</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Serrano i Plana, Núria</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Ariño Blasco, Cristina</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Díaz Cruz, José Manuel</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Esteban i Cortada, Miquel</mods:namePart>
               </mods:name>
               <mods:originInfo>
                  <mods:dateIssued encoding="iso8601">2019-09-05T12:06:19Z2019-09-05T12:06:19Z2015-10-282019-09-05T12:06:20Z</mods:dateIssued>
               </mods:originInfo>
               <mods:identifier type="none"/>
               <mods:abstract>An Ex-situ antimony film screen-printed carbon electrode (Ex-situ SbSPCE) was successfully applied for the determination of Ni(II), by means of adsorptive stripping voltammetry using dimethylglyoxime as complexing agent, in a certified reference wastewater sample. This electrode is proposed as an alternative to more conventional antimony film electrodes. Ex-situ SbSPCE was analytically characterized and the obtained parameters suggest that Ex-situ SbSPCE behaves much better than both Ex-situ BiSPCE and BispSPE for Ni(II) determination. The results confirm the applicability of Ex-situ SbSPCE for the determination of low concentration levels of Ni(II) in natural samples with a very high reproducibility and good trueness.</mods:abstract>
               <mods:language>
                  <mods:languageTerm authority="rfc3066"/>
               </mods:language>
               <mods:accessCondition type="useAndReproduction">(c) Wiley-VCH, 2015 info:eu-repo/semantics/openAccess</mods:accessCondition>
               <mods:subject>
                  <mods:topic>Níquel</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Voltametria</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Anàlisi electroquímica</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Nickel</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Voltammetry</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Electrochemical analysis</mods:topic>
               </mods:subject>
               <mods:titleInfo>
                  <mods:title>Ex-situ antimony screen-printed carbon electrode for voltammetric determination of Ni(II) - ions in wastewater</mods:title>
               </mods:titleInfo>
               <mods:genre>info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion</mods:genre>
            </mods:mods>
         </xmlData>
      </mdWrap>
   </dmdSec>
   <structMap LABEL="DSpace Object" TYPE="LOGICAL">
      <div TYPE="DSpace Object Contents" ADMID="DMD_2445_139347"/>
   </structMap>
</mets></metadata></record></GetRecord></OAI-PMH>