<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-13T04:02:56Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2117/381625" metadataPrefix="mets">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2117/381625</identifier><datestamp>2026-01-16T10:00:17Z</datestamp><setSpec>com_2072_1033</setSpec><setSpec>col_2072_452950</setSpec></header><metadata><mets xmlns="http://www.loc.gov/METS/" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" ID="&#xa;&#x9;&#x9;&#x9;&#x9;DSpace_ITEM_2117-381625" TYPE="DSpace ITEM" PROFILE="DSpace METS SIP Profile 1.0" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd" OBJID="&#xa;&#x9;&#x9;&#x9;&#x9;hdl:2117/381625">
   <metsHdr CREATEDATE="2026-04-13T06:02:56Z">
      <agent ROLE="CUSTODIAN" TYPE="ORGANIZATION">
         <name>RECERCAT</name>
      </agent>
   </metsHdr>
   <dmdSec ID="DMD_2117_381625">
      <mdWrap MDTYPE="MODS">
         <xmlData xmlns:mods="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
            <mods:mods xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Komary, Mahyad</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Komarizadehasl, Seyedmilad</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Tošić, Nikola</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Segura Pérez, Ignacio</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Lozano Galant, José Antonio</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Turmo Coderque, José</mods:namePart>
               </mods:name>
               <mods:originInfo>
                  <mods:dateIssued encoding="iso8601">2023-02</mods:dateIssued>
               </mods:originInfo>
               <mods:identifier type="none"/>
               <mods:abstract>Globally, corrosion is the costliest cause of the deterioration of metallic and concrete structures, leading to significant financial losses and unexpected loss of life. Therefore, corrosion monitoring is vital to the assessment of structures’ residual performance and for the identification of pathologies in early stages for the predictive maintenance of facilities. However, the high price tag on available corrosion monitoring systems leads to their exclusive use for structural health monitoring applications, especially for atmospheric corrosion detection in civil structures. In this paper a systematic literature review is provided on the state-of-the-art electrochemical methods and physical methods used so far for corrosion monitoring compatible with low-cost sensors and data acquisition devices for metallic and concrete structures. In addition, special attention is paid to the use of these devices for corrosion monitoring and detection for in situ applications in different industries. This analysis demonstrates the possible applications of low-cost sensors in the corrosion monitoring sector. In addition, this study provides scholars with preferred techniques and the most common microcontrollers, such as Arduino, to overcome the corrosion monitoring difficulties in the construction industry.The authors are indebted to the projects PID2021‐126405OB‐C31 and PID2021‐126405OB‐C32 funded by FEDER funds—A Way to Make Europe and Spanish Ministry of Economy and Com‐petitiveness MICIN/AEI/10.13039/501100011033/, project PID2019‐106555RB‐I00 and project IDEAS 2.14 from Ports 4.0. It should also be noted that funding for this research was provided for Seyed‐milad Komarizadehasl by the European Social Fund and the Spanish Agencia Estatal de Investi‐gación del Ministerio de Ciencia Innovación y Universidades, grant (PRE2018‐083238).Peer ReviewedPostprint (published version)</mods:abstract>
               <mods:language>
                  <mods:languageTerm authority="rfc3066"/>
               </mods:language>
               <mods:accessCondition type="useAndReproduction">http://creativecommons.org/licenses/by/4.0/ Open Access Attribution 4.0 International</mods:accessCondition>
               <mods:subject>
                  <mods:topic>Àrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Structural health monitoring</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Corrosion monitoring</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Electrochemical sensors</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Data acquisition</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Data analysis</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Physical methods</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Structural health monitoring</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Low-cost sensors</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Atmospheric corrosion</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Monitorització de salut estructural</mods:topic>
               </mods:subject>
               <mods:titleInfo>
                  <mods:title>Low-cost technologies used in corrosion monitoring</mods:title>
               </mods:titleInfo>
               <mods:genre>Article</mods:genre>
            </mods:mods>
         </xmlData>
      </mdWrap>
   </dmdSec>
   <structMap LABEL="DSpace Object" TYPE="LOGICAL">
      <div TYPE="DSpace Object Contents" ADMID="DMD_2117_381625"/>
   </structMap>
</mets></metadata></record></GetRecord></OAI-PMH>