<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-14T09:07:48Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2117/369180" metadataPrefix="oai_dc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2117/369180</identifier><datestamp>2025-07-22T20:19:34Z</datestamp><setSpec>com_2072_1033</setSpec><setSpec>col_2072_452951</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Discontinuous tests for EMC disturbances in the time domain</dc:title>
   <dc:creator>Rendón Vélez, Simón</dc:creator>
   <dc:contributor>Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica</dc:contributor>
   <dc:contributor>Silva Martínez, Fernando</dc:contributor>
   <dc:subject>Àrees temàtiques de la UPC::Enginyeria electrònica</dc:subject>
   <dc:subject>Electromagnetic interference</dc:subject>
   <dc:subject>EMC</dc:subject>
   <dc:subject>discontinuous disturbances</dc:subject>
   <dc:subject>conducted emissions</dc:subject>
   <dc:subject>Interferència electromagnètica</dc:subject>
   <dc:description>Measurement of electromagnetic interference has been performed in the past by EMI receivers operating in the frequency domain. Particularly, to measure discontinuous disturbances (clicks), an EMI receiver connected to a disturbance analyzer is needed. The EMI receiver is used to measure the interference in a particular frequency. At the output of the intermediate frequency, the analyzer is connected for the clicks' evaluation. The measurement is repeated at four frequencies. This disturbance analysis can take up to 16 hours for the click evaluation of one device under test. Measurements of electromagnetic interference in the time-domain allow reducing the scan time in comparison to EMI receivers. In this MSc project, a full-time domain EMI measurement system covering the frequency range 150 kHz - 30 MHz is proposed to measure emissions according to CISPR 16-1-1, and perform the discontinuous disturbance analysis as described by UNE 55014.</dc:description>
   <dc:date>2021-09-16</dc:date>
   <dc:type>Master thesis</dc:type>
   <dc:identifier>https://hdl.handle.net/2117/369180</dc:identifier>
   <dc:identifier>ETSETB-230.162008</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:rights>S'autoritza la difusió de l'obra mitjançant la llicència Creative Commons o similar 'Reconeixement-NoComercial- SenseObraDerivada'</dc:rights>
   <dc:rights>Open Access</dc:rights>
   <dc:format>application/zip</dc:format>
   <dc:format>application/pdf</dc:format>
   <dc:publisher>Universitat Politècnica de Catalunya</dc:publisher>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>