<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-13T02:09:49Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2117/26571" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2117/26571</identifier><datestamp>2026-01-30T08:58:38Z</datestamp><setSpec>com_2072_1033</setSpec><setSpec>col_2072_452950</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Robustness analysis of sensor placement for leak detection and location under uncertain operating conditions</dc:title>
   <dc:creator>Blesa Izquierdo, Joaquim</dc:creator>
   <dc:creator>Nejjari Akhi-Elarab, Fatiha</dc:creator>
   <dc:creator>Sarrate Estruch, Ramon</dc:creator>
   <dc:subject>Àrees temàtiques de la UPC::Informàtica::Automàtica i control</dc:subject>
   <dc:subject>Observation (Scientific method)</dc:subject>
   <dc:subject>Robust control</dc:subject>
   <dc:subject>Water - Distribution</dc:subject>
   <dc:subject>observability</dc:subject>
   <dc:subject>sensor placement</dc:subject>
   <dc:subject>leak location</dc:subject>
   <dc:subject>clustering</dc:subject>
   <dc:subject>robustness analysis</dc:subject>
   <dc:subject>Observació (Mètode científic)</dc:subject>
   <dc:subject>Control de robustesa</dc:subject>
   <dc:subject>Aigua--Distribució</dc:subject>
   <dcterms:abstract>Some pressure sensor placement methods for leak detection and location in water distribution networks are based on the pressure sensitivity matrix analysis. This matrix depends on the network demands, which are nondeterministic, and the leak magnitudes, which are unknown. In this paper, the robustness of a sensor placement methodology against the fault sensitivity matrix uncertainty is studied. The robustness study is illustrated by means of a small academic network as well as a district metered area in the Barcelona water distribution network. Results reveal that this uncertainty should be taken into account in the sensor placement methodology.</dcterms:abstract>
   <dcterms:abstract>Peer Reviewed</dcterms:abstract>
   <dcterms:abstract>Postprint (published version)</dcterms:abstract>
   <dcterms:issued>2014</dcterms:issued>
   <dc:type>Conference report</dc:type>
   <dc:relation>http://dx.doi.org/10.1016/j.proeng.2014.11.453</dc:relation>
   <dc:relation>info:eu-repo/grantAgreement/EC/FP7/318556/EU/Efficient Integrated Real-time Monitoring and Control of Drinking Water Networks/EFFINET</dc:relation>