<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-19T09:34:43Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2117/17592" metadataPrefix="didl">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2117/17592</identifier><datestamp>2025-07-17T09:35:44Z</datestamp><setSpec>com_2072_1033</setSpec><setSpec>col_2072_452950</setSpec></header><metadata><d:DIDL xmlns:d="urn:mpeg:mpeg21:2002:02-DIDL-NS" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="urn:mpeg:mpeg21:2002:02-DIDL-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didl.xsd">
   <d:Item id="hdl_2117_17592">
      <d:Descriptor>
         <d:Statement mimeType="application/xml; charset=utf-8">
            <dii:Identifier xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS" xsi:schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd">urn:hdl:2117/17592</dii:Identifier>
         </d:Statement>
      </d:Descriptor>
      <d:Descriptor>
         <d:Statement mimeType="application/xml; charset=utf-8">
            <oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
               <dc:title>Monte Carlo simulation of the total dose distribution around the 12 MeV UPC race-track microtron and radiation shielding calculations</dc:title>
               <dc:creator>De la Fuente, Cristina</dc:creator>
               <dc:creator>Duch Guillen, María Amor</dc:creator>
               <dc:creator>Koubychine Merkulov, Youri Alexandrovich</dc:creator>
               <dc:creator>Shvedunov, V.I.</dc:creator>
               <dc:subject>Àrees temàtiques de la UPC::Matemàtiques i estadística::Estadística matemàtica</dc:subject>
               <dc:subject>Àrees temàtiques de la UPC::Física::Electromagnetisme</dc:subject>
               <dc:subject>Monte Carlo method</dc:subject>
               <dc:subject>Radiation</dc:subject>
               <dc:subject>Monte Carlo, Mètode de</dc:subject>
               <dc:subject>Radiació</dc:subject>
               <dc:description>The Technical University of Catalonia is building a&#xd;
miniature 12 MeV electron race-track microtron for&#xd;
medical applications. In the paper we study the leakage&#xd;
radiation caused by beam losses inside the accelerator&#xd;
head, as well as the bremsstrahlung radiation produced by&#xd;
the primary beam in the commissioning setting. Results of&#xd;
Monte Carlo simulations using the PENELOPE code are&#xd;
presented and two shielding schemes, global and local,&#xd;
are studied. The obtained shielding parameters are&#xd;
compared with estimates based on DIN 6847 part 2 as&#xd;
international recommendation of the radiation safety&#xd;
standards.</dc:description>
               <dc:description>Postprint (published version)</dc:description>
               <dc:date>2012</dc:date>
               <dc:type>Conference lecture</dc:type>
               <dc:relation>http://accelconf.web.cern.ch/AccelConf/IPAC2011/papers/wepc165.pdf</dc:relation>
               <dc:rights>http://creativecommons.org/licenses/by-nc-nd/3.0/es/</dc:rights>
               <dc:rights>Open Access</dc:rights>
               <dc:rights>Attribution-NonCommercial-NoDerivs 3.0 Spain</dc:rights>
            </oai_dc:dc>
         </d:Statement>
      </d:Descriptor>
   </d:Item>
</d:DIDL></metadata></record></GetRecord></OAI-PMH>