<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-14T04:39:37Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2117/13307" metadataPrefix="oai_dc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2117/13307</identifier><datestamp>2026-02-11T06:34:04Z</datestamp><setSpec>com_2072_1033</setSpec><setSpec>col_2072_452950</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Improved neutron capture cross section measurements with the n_TOF total absorption Cclorimeter</dc:title>
   <dc:creator>Calviño Tavares, Francisco</dc:creator>
   <dc:creator>Cortés Rossell, Guillem Pere</dc:creator>
   <dc:creator>Gómez Hornillos, María Belén</dc:creator>
   <dc:contributor>Universitat Politècnica de Catalunya. Departament de Física i Enginyeria Nuclear</dc:contributor>
   <dc:contributor>Universitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions</dc:contributor>
   <dc:subject>Àrees temàtiques de la UPC::Energies::Energia nuclear</dc:subject>
   <dc:subject>Nuclear energy</dc:subject>
   <dc:subject>Monte Carlo method</dc:subject>
   <dc:subject>Monte Carlo, Mètode de</dc:subject>
   <dc:subject>Energia nuclear</dc:subject>
   <dc:description>The n TOF collaboration operates a Total Absorption Calorimeter (TAC) [1] for measuring neu-&#xd;
tron capture cross-sections of low-mass and/or radioactive samples. The results obtained with the&#xd;
TAC have led to a substantial improvement of the capture cross sections of 237Np and 240Pu [2].&#xd;
The experience acquired during the  rst measurements has allowed us to optimize the performance&#xd;
of the TAC and to improve the capture signal to background ratio, thus opening the way to more&#xd;
complex and demanding measurements on rare radioactive materials. The new design has been&#xd;
reached by a series of detailed Monte Carlo simulations of complete experiments and dedicated test&#xd;
measurements. The new capture setup will be presented and the main achievements highlighted.</dc:description>
   <dc:description>Postprint (published version)</dc:description>
   <dc:date>2011-08-12</dc:date>
   <dc:type>Article</dc:type>
   <dc:identifier>Calviño, F.; Cortes, G.; Gómez, M. Improved neutron capture cross section measurements with the n_TOF total absorption Cclorimeter. "Journal of the Korean Physical Society", 12 Agost 2011, vol. 59, núm. 2, p. 1813-1816.</dc:identifier>
   <dc:identifier>0374-4884</dc:identifier>
   <dc:identifier>https://hdl.handle.net/2117/13307</dc:identifier>
   <dc:identifier>10.3938/jkps.59.1813</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:rights>http://creativecommons.org/licenses/by-nc-nd/3.0/es/</dc:rights>
   <dc:rights>Restricted access - publisher's policy</dc:rights>
   <dc:rights>Attribution-NonCommercial-NoDerivs 3.0 Spain</dc:rights>
   <dc:format>4 p.</dc:format>
   <dc:format>application/pdf</dc:format>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>