<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-13T13:21:55Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:2117/116097" metadataPrefix="didl">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:2117/116097</identifier><datestamp>2025-07-17T08:43:05Z</datestamp><setSpec>com_2072_1033</setSpec><setSpec>col_2072_452950</setSpec></header><metadata><d:DIDL xmlns:d="urn:mpeg:mpeg21:2002:02-DIDL-NS" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="urn:mpeg:mpeg21:2002:02-DIDL-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didl.xsd">
   <d:Item id="hdl_2117_116097">
      <d:Descriptor>
         <d:Statement mimeType="application/xml; charset=utf-8">
            <dii:Identifier xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS" xsi:schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd">urn:hdl:2117/116097</dii:Identifier>
         </d:Statement>
      </d:Descriptor>
      <d:Descriptor>
         <d:Statement mimeType="application/xml; charset=utf-8">
            <oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
               <dc:title>Huge reduction of defibrillation thresholds using four electrode defibrillators</dc:title>
               <dc:creator>Simic, Ana</dc:creator>
               <dc:creator>Rodríguez Cantalapiedra, Inma</dc:creator>
               <dc:creator>Elorza Barbajero, Jorge</dc:creator>
               <dc:creator>Bragard, Jean</dc:creator>
               <dc:subject>Àrees temàtiques de la UPC::Física</dc:subject>
               <dc:subject>Defibrillators</dc:subject>
               <dc:subject>defibrillation thresholds&#xd;
defibrillators</dc:subject>
               <dc:subject>Desfibril·ladors</dc:subject>
               <dc:description>In the absence of a better solution, ventricular fibril-&#xd;
lation is treated by applying one or several large electri-&#xd;
cal shocks to the patient. The question of how to lower&#xd;
the energy required for a successful shock is still a cur-&#xd;
rent issue in both fundamental research and clinical prac-&#xd;
tice. In the study presented here we will compare defib-&#xd;
rillation applied through a four electrode device with the&#xd;
standard procedure using two electrodes. The method is&#xd;
tested through intensive numerical simulations. Here we&#xd;
have used a one dimensional geometry. At the level of&#xd;
the cardiac tissue, the bidomain and the modified Beeler-&#xd;
Reuter models were used. Three different shock waveforms&#xd;
are tested: monophasic and two types of biphasic shocks.&#xd;
The results are compared with those obtained with stan-&#xd;
dard two electrode device. A significant reduction in de-&#xd;
fibrillation thresholds is achieved for all the three tested&#xd;
waveforms when we use a four electrode device.</dc:description>
               <dc:description>Postprint (published version)</dc:description>
               <dc:date>2015-01-02</dc:date>
               <dc:type>Article</dc:type>
               <dc:relation>http://www.cinc.org/archives/2014/pdf/0505.pdf</dc:relation>
               <dc:rights>http://creativecommons.org/licenses/by-nc-nd/3.0/es/</dc:rights>
               <dc:rights>Open Access</dc:rights>
               <dc:rights>Attribution-NonCommercial-NoDerivs 3.0 Spain</dc:rights>
            </oai_dc:dc>
         </d:Statement>
      </d:Descriptor>
   </d:Item>
</d:DIDL></metadata></record></GetRecord></OAI-PMH>