<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-13T06:22:46Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:20.500.12328/4543" metadataPrefix="didl">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:20.500.12328/4543</identifier><datestamp>2025-05-16T12:50:28Z</datestamp><setSpec>com_2072_67741</setSpec><setSpec>col_2072_484352</setSpec></header><metadata><d:DIDL xmlns:d="urn:mpeg:mpeg21:2002:02-DIDL-NS" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="urn:mpeg:mpeg21:2002:02-DIDL-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didl.xsd">
   <d:DIDLInfo>
      <dcterms:created xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/dcterms.xsd">2025-05-16T12:50:28Z</dcterms:created>
   </d:DIDLInfo>
   <d:Item id="hdl_20.500.12328_4543">
      <d:Descriptor>
         <d:Statement mimeType="application/xml; charset=utf-8">
            <dii:Identifier xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS" xsi:schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd">urn:hdl:20.500.12328/4543</dii:Identifier>
         </d:Statement>
      </d:Descriptor>
      <d:Descriptor>
         <d:Statement mimeType="application/xml; charset=utf-8">
            <oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
               <dc:title>Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study</dc:title>
               <dc:creator>Gargallo-Albiol, Jordi</dc:creator>
               <dc:creator>Zilleruelo-Pozo, María José</dc:creator>
               <dc:creator>Lucas-Taulé, Ernest</dc:creator>
               <dc:creator>Muñoz Peñalver, Jesús</dc:creator>
               <dc:creator>Paternostro-Betancourt, Daniel</dc:creator>
               <dc:creator>Hernandez Alfaro, Federico</dc:creator>
               <dc:subject>Precisió</dc:subject>
               <dc:subject>Cirurgia assistida per ordinador</dc:subject>
               <dc:subject>Assistida per ordinador</dc:subject>
               <dc:subject>Imatge tridimensional</dc:subject>
               <dc:subject>Implants dentals</dc:subject>
               <dc:subject>Precisión</dc:subject>
               <dc:subject>Cirugía asistida por computadora</dc:subject>
               <dc:subject>Cirugía asistida por computadora</dc:subject>
               <dc:subject>Imágenes tridimensionales</dc:subject>
               <dc:subject>Implantes dentales</dc:subject>
               <dc:subject>Accuracy</dc:subject>
               <dc:subject>Computer-aided surgery</dc:subject>
               <dc:subject>Computer-assisted</dc:subject>
               <dc:subject>Three-dimensional imaging</dc:subject>
               <dc:subject>Dental implants</dc:subject>
               <dc:description>Objective: A cohort prospective study was conducted to assess the three-dimensional positioning accuracy of the implant between pre-surgical and the final implant position using a static fully guided approach in the posterior area of the jaws. Materials and methods: A total of 60 implants (30 patients) were digitally analyzed after superimposing the Digital Imaging and Communications in Medicine (DICOM) files obtained from the Cone Beam Computed Tomography (CBCT) pre- and post-implant placement. The software calculations included deviations at the implant shoulder and at the implant apex, global deviation (3D offset), and angle deviation. Statistical analysis was performed with α = 0.05. Results: Considering the total number of implants, mesiodistal, buccolingual, and apicocoronal mean deviations at the shoulder and implant apex were equal or below 0.21 ± 0.69 mm, and only the buccolingual mean deviation at the apex reached up to 0.67 ± 1.06 mm. The mesiodistal and apicocoronal deviations were not statistically significant at both the shoulder and apex levels of the implant. The mean total angular deviation was 5.62° ± 4.09. The main limitation of this surgical approach was the requirement for a wide mouth opening. Conclusions: Static fully guided surgery for dental implant placement exhibits minimum deviations respect to presurgical planning. The main limitation in the posterior areas is the requirement for a wide mouth opening. Clinical relevance: Even with minimum deviations clinically acceptable, precautions and safety margins must be respected when using static full-guided surgery to place dental implants.</dc:description>
               <dc:date>2025-05-16T12:50:28Z</dc:date>
               <dc:date>2025-05-16T12:50:28Z</dc:date>
               <dc:date>2022</dc:date>
               <dc:type>info:eu-repo/semantics/article</dc:type>
               <dc:identifier>Gargallo-Albiol, Jordi; Zilleruelo-Pozo, María José; Lucas-Taulé, Ernest [et al.]. Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study. Clinical Oral Investigations, 2022, 26, p. 2783-2791. Disponible en: &lt;https://link.springer.com/article/10.1007/s00784-021-04254-3>. Fecha de acceso: 16 ene. 2025. DOI: 10.1007/s00784-021-04254-3</dc:identifier>
               <dc:identifier>1436-3771</dc:identifier>
               <dc:identifier>http://hdl.handle.net/20.500.12328/4543</dc:identifier>
               <dc:identifier>https://dx.doi.org/10.1007/s00784-021-04254-3</dc:identifier>
               <dc:language>eng</dc:language>
               <dc:relation>Clinical Oral Investigations</dc:relation>
               <dc:relation>26</dc:relation>
               <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
               <dc:rights>© 2022 Springer Nature</dc:rights>
               <dc:publisher>Springer Nature</dc:publisher>
            </oai_dc:dc>
         </d:Statement>
      </d:Descriptor>
   </d:Item>
</d:DIDL></metadata></record></GetRecord></OAI-PMH>