<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-18T01:40:20Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:20.500.12328/3488" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:20.500.12328/3488</identifier><datestamp>2025-05-16T12:53:03Z</datestamp><setSpec>com_2072_67741</setSpec><setSpec>col_2072_484352</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Clinical evidence on a novel macrohybrid design dental implant with 12° angled platform: a systematic review</dc:title>
   <dc:creator>Andrea, Galve-Huertas</dc:creator>
   <dc:creator>Zilleruelo-Pozo, Maria José</dc:creator>
   <dc:creator>García González, Susana</dc:creator>
   <dc:creator>Ortíz-Puigpelat, Octavi</dc:creator>
   <dc:creator>Hernandez Alfaro, Federico</dc:creator>
   <dc:creator>Aboul-Hosn Centenero, Samir Carlos</dc:creator>
   <dc:subject>Implant coaxial</dc:subject>
   <dc:subject>Angulació de l'implant</dc:subject>
   <dc:subject>Percentatge d'èxit</dc:subject>
   <dc:subject>Pèrdua òssia marginal</dc:subject>
   <dc:subject>Implante coaxial</dc:subject>
   <dc:subject>Angulación del implante</dc:subject>
   <dc:subject>Tasa de éxito</dc:subject>
   <dc:subject>Pérdida de hueso marginal</dc:subject>
   <dc:subject>Coaxis implant</dc:subject>
   <dc:subject>Implant angulation</dc:subject>
   <dc:subject>Success rate</dc:subject>
   <dc:subject>Marginal bone loss</dc:subject>
   <dcterms:abstract>Background: Immediate implant placement with immediate esthetics has become a more common procedure over time, though ensuring good emergence of the axis of the implant has been a challenge. A novel macroimplant design with an angled platform (Co-Axis®) has been developed to ensure exit of the head of the implant in the correct prosthetic position. A systematic literature review was carried to determine the survival rate and marginal bone loss associated with these implants. Material and Methods: An electronic and manual literature search was made in accordance with the PRISMA statement. The search strategy was limited to human studies, retrospective and prospective clinical trials, cross-sectional studies, and cohort studies reporting outcomes of a novel macrohybrid implant with a 12° angled implant connection. Results: Three articles met the inclusion criteria and were reviewed in the analysis. The estimated success rate was 95.9%. The global marginal bone loss was estimated to be −0.17 ± 0.58 mm in an environment characterized by great heterogeneity (I2 = 99%). The estimated mean implant stability was 69.6 ± 0.92 (ISQ). As only two studies provided the required information, it was not possible to determine publication bias. Lastly, mean recession was estimated to be practically zero (0.06 ± 0.23 mm), with great heterogeneity. Conclusions: Within the limitations of this systematic review, it can be affirmed that immediate implant treatment with Co-Axis® implants shows a survival rate of 95.9% at one year of follow-up, with low marginal bone loss values, near-zero soft tissue recession, and favorable papilla index values. Nevertheless, the great heterogeneity of the data requires the findings to be interpreted with caution.</dcterms:abstract>
   <dcterms:dateAccepted>2025-05-16T12:53:03Z</dcterms:dateAccepted>
   <dcterms:available>2025-05-16T12:53:03Z</dcterms:available>
   <dcterms:created>2025-05-16T12:53:03Z</dcterms:created>
   <dcterms:issued>2022</dcterms:issued>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:identifier>Galve-Huertas, Andrea; Zilleruelo-Pozo, Maria José; García González, Susana [et al.]. Clinical evidence on a novel macrohybrid design dental implant with 12° angled platform: a systematic review. Materials, 2022, 15(14), 5011. Disponible en: &lt;https://www.mdpi.com/1996-1944/15/14/5011>. Fecha de acceso: 4 nov. 2022. DOI: 10.3390/ma15145011</dc:identifier>
   <dc:identifier>1996-1944</dc:identifier>
   <dc:identifier>http://hdl.handle.net/20.500.12328/3488</dc:identifier>
   <dc:identifier>https://dx.doi.org/10.3390/ma15145011</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:relation>Materials</dc:relation>
   <dc:relation>15;14</dc:relation>
   <dc:relation>https://www.mdpi.com/1996-1944/15/14/5011</dc:relation>
   <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:rights>This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</dc:rights>
   <dc:publisher>MDPI</dc:publisher>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>