<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-13T05:57:56Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:11351/9691" metadataPrefix="mets">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:11351/9691</identifier><datestamp>2025-10-24T10:59:28Z</datestamp><setSpec>com_2072_451665</setSpec><setSpec>com_2072_378040</setSpec><setSpec>col_2072_451666</setSpec></header><metadata><mets xmlns="http://www.loc.gov/METS/" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" ID="&#xa;&#x9;&#x9;&#x9;&#x9;DSpace_ITEM_11351-9691" TYPE="DSpace ITEM" PROFILE="DSpace METS SIP Profile 1.0" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd" OBJID="&#xa;&#x9;&#x9;&#x9;&#x9;hdl:11351/9691">
   <metsHdr CREATEDATE="2026-04-13T07:57:56Z">
      <agent ROLE="CUSTODIAN" TYPE="ORGANIZATION">
         <name>RECERCAT</name>
      </agent>
   </metsHdr>
   <dmdSec ID="DMD_11351_9691">
      <mdWrap MDTYPE="MODS">
         <xmlData xmlns:mods="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
            <mods:mods xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Jofre, Marc</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Romeu, Jordi</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>JOFRE-ROCA, Lluis</mods:namePart>
               </mods:name>
               <mods:extension>
                  <mods:dateAccessioned encoding="iso8601">2025-10-24T10:59:28Z</mods:dateAccessioned>
               </mods:extension>
               <mods:extension>
                  <mods:dateAvailable encoding="iso8601">2025-10-24T10:59:28Z</mods:dateAvailable>
               </mods:extension>
               <mods:originInfo>
                  <mods:dateIssued encoding="iso8601">2023-06-08T10:37:12Z2023-06-08T10:37:12Z2023-01-30</mods:dateIssued>
               </mods:originInfo>
               <mods:identifier type="none"/>
               <mods:identifier type="uri">http://hdl.handle.net/11351/9691</mods:identifier>
               <mods:abstract>Droplets; Magnetometry; MicrofluidicsGotetes; Magnetometria; MicrofluídicaGotitas; Magnetometría; MicrofluidosQuantum sensors provide unprecedented magnetic field detection sensitivities, enabling these to extend the common magnetometry range of applications and environments of operation. In this framework, many applications also require high spatial resolution magnetic measurements for biomedical research, environmental monitoring and industrial production. In this regard, optically pumped magnetometers (OPMs) are considered as prominent candidates, but are impaired in size with micrometer scale magnetic particles, e.g. magnetic droplets. In order to address this limitation, here we study the effects of adding a micrometer-to-millimeter magnetic guide to a miniature OPM. This device is applied to detect Fe3O4 magnetic droplets flowing at rates up to 25&#xd;
drop. s−1 in a microfluidic channel. The computed spatial resolution is 300 µm and the measured signal-to-noise ratio is larger than 15 dB for the different sizes of considered magnetic droplets.</mods:abstract>
               <mods:language>
                  <mods:languageTerm authority="rfc3066"/>
               </mods:language>
               <mods:accessCondition type="useAndReproduction">Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess</mods:accessCondition>
               <mods:subject>
                  <mods:topic>Detectors</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Magnetòmetres</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Geofísica</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Investigative Techniques::Magnetometry</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Investigative Techniques::Rheology::Microfluidics</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>DISCIPLINES AND OCCUPATIONS::Natural Science Disciplines::Science::Research::Biomedical Research</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::técnicas de investigación::magnetometría</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::técnicas de investigación::reología::microfluídica</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>DISCIPLINAS Y OCUPACIONES::disciplinas de las ciencias naturales::ciencia::investigación::investigación biomédica</mods:topic>
               </mods:subject>
               <mods:titleInfo>
                  <mods:title>Optically pumped magnetometer with high spatial resolution magnetic guide for the detection of magnetic droplets in a microfluidic channel</mods:title>
               </mods:titleInfo>
               <mods:genre>info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion</mods:genre>
            </mods:mods>
         </xmlData>
      </mdWrap>
   </dmdSec>
   <structMap LABEL="DSpace Object" TYPE="LOGICAL">
      <div TYPE="DSpace Object Contents" ADMID="DMD_11351_9691"/>
   </structMap>
</mets></metadata></record></GetRecord></OAI-PMH>