<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-17T14:31:13Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:11351/13748" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:11351/13748</identifier><datestamp>2025-10-24T10:17:39Z</datestamp><setSpec>com_2072_378070</setSpec><setSpec>com_2072_378040</setSpec><setSpec>col_2072_378092</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up</dc:title>
   <dc:creator>Bertolani, Yann</dc:creator>
   <dc:creator>Rigo-Quera, Jaume</dc:creator>
   <dc:creator>Sánchez Vela, Laura</dc:creator>
   <dc:creator>Pujol, Olívia</dc:creator>
   <dc:creator>Amilburu, Manuel</dc:creator>
   <dc:creator>Dou, Antonio</dc:creator>
   <dc:creator>Castany, Marta</dc:creator>
   <dc:subject>Avaluació de resultats (Assistència sanitària)</dc:subject>
   <dc:subject>Glaucoma - Cirurgia endoscòpica</dc:subject>
   <dc:subject>Pròtesis de Stent</dc:subject>
   <dc:subject>ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Prognosis::Treatment Outcome</dc:subject>
   <dc:subject>ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Surgical Procedures, Operative::Minimally Invasive Surgical Procedures</dc:subject>
   <dc:subject>DISEASES::Eye Diseases::Ocular Hypertension::Glaucoma</dc:subject>
   <dc:subject>Other subheadings::Other subheadings::Other subheadings::/surgery</dc:subject>
   <dc:subject>ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Equipment and Supplies::Prostheses and Implants::Stents</dc:subject>
   <dc:subject>TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::pronóstico::resultado del tratamiento</dc:subject>
   <dc:subject>TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::intervenciones quirúrgicas::procedimientos quirúrgicos mínimamente invasivos</dc:subject>
   <dc:subject>ENFERMEDADES::oftalmopatías::hipertensión ocular::glaucoma</dc:subject>
   <dc:subject>Otros calificadores::Otros calificadores::Otros calificadores::/cirugía</dc:subject>
   <dc:subject>TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::equipos y suministros::prótesis e implantes::stents</dc:subject>
   <dcterms:abstract>Intraocular surgery; Minimally invasive glaucoma surgery; Open-conjunctiva approach</dcterms:abstract>
   <dcterms:abstract>Cirugía intraocular; Cirugía de glaucoma mínimamente invasiva; Abordaje conjuntival abierto</dcterms:abstract>
   <dcterms:abstract>Cirurgia intraocular; Cirurgia de glaucoma mínimament invasiva; Abordatge conjuntival obert</dcterms:abstract>
   <dcterms:abstract>Background: To compare the efficacy and safety of the XEN® 63 µm and 45 µm devices with the ab externo open conjunctiva with a 30G needle approach. Methods: A retrospective, non-randomized and single-center study was conducted. Consecutive eyes undergoing a XEN® 63 µm implant were compared with a matched cohort of cases with a XEN® 45 µm implant. Standalone and combined procedures with phacoemulsification were included. Results: A total of 28 XEN® 45 µm and 28 XEN® 63 µm were included. Complete surgical success was achieved in 17 cases (60.7%) in the 45 µm group and in 20 cases (71.4%) in the 63 µm group, with no statistical differences. One year after the surgery, the mean IOP was 13.8 ± 3.3 mmHg for the 45 µm group and 12.4 ± 4.2 mmHg for the 63 µm group (p-value > 0.05). Likewise, the use of glaucoma medication was lowered in the 63 µm device (0.32 ± 0.87) compared to the 45 µm device (0.39 ± 0.86), with no statistical significance. Postoperative hypotony was more frequent in the 63 µm device (39.3%) than in the 45 µm group (28.6%), with no statistical differences. However, hypotony-associated complications (including choroidal detachment, hypotony keratopathy, and hypotony maculopathy) were significantly higher in the 63 µm group (p = 0.011). Conclusions: Although the XEN® 63 µm may offer a greater IOP-lowering effect with better complete surgical success, no significant differences were detected compared to the 45 µm device. Hypotony-related complications were higher in the XEN 63 µm, although most of them resolved with conservative management.</dcterms:abstract>
   <dcterms:dateAccepted>2025-10-24T10:17:39Z</dcterms:dateAccepted>
   <dcterms:available>2025-10-24T10:17:39Z</dcterms:available>
   <dcterms:created>2025-10-24T10:17:39Z</dcterms:created>
   <dcterms:issued>2025-09-29T12:28:16Z</dcterms:issued>
   <dcterms:issued>2025-09-29T12:28:16Z</dcterms:issued>
   <dcterms:issued>2025-05</dcterms:issued>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
   <dc:identifier>http://hdl.handle.net/11351/13748</dc:identifier>
   <dc:relation>Journal of Clinical Medicine;14(10)</dc:relation>
   <dc:relation>https://doi.org/10.3390/jcm14103545</dc:relation>
   <dc:rights>Attribution 4.0 International</dc:rights>
   <dc:rights>http://creativecommons.org/licenses/by/4.0/</dc:rights>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:publisher>MDPI</dc:publisher>
   <dc:source>Scientia</dc:source>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>