<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-13T00:57:31Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:11351/12943" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:11351/12943</identifier><datestamp>2025-10-24T10:37:54Z</datestamp><setSpec>com_2072_378070</setSpec><setSpec>com_2072_378040</setSpec><setSpec>col_2072_378092</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Impact of the restrictive technique on outcomes in Baerveldt-350 implant surgery</dc:title>
   <dc:creator>Segura-Duch, Gloria</dc:creator>
   <dc:creator>Duch, Susana</dc:creator>
   <dc:creator>Schilt-Catafal, Maria del Mar</dc:creator>
   <dc:creator>Arciniegas-Perasso, Carlos</dc:creator>
   <dc:creator>Oliver-Gutierrez, David</dc:creator>
   <dc:subject>Glaucoma - Cirurgia</dc:subject>
   <dc:subject>Pressió intraocular</dc:subject>
   <dc:subject>Lents intraoculars</dc:subject>
   <dc:subject>Pròtesis de Stent</dc:subject>
   <dc:subject>DISEASES::Eye Diseases::Ocular Hypertension::Glaucoma</dc:subject>
   <dc:subject>Other subheadings::Other subheadings::Other subheadings::/surgery</dc:subject>
   <dc:subject>PHENOMENA AND PROCESSES::Ocular Physiological Phenomena::Intraocular Pressure</dc:subject>
   <dc:subject>ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Equipment and Supplies::Prostheses and Implants::Glaucoma Drainage Implants</dc:subject>
   <dc:subject>ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Equipment and Supplies::Prostheses and Implants::Stents</dc:subject>
   <dc:subject>ENFERMEDADES::oftalmopatías::hipertensión ocular::glaucoma</dc:subject>
   <dc:subject>Otros calificadores::Otros calificadores::Otros calificadores::/cirugía</dc:subject>
   <dc:subject>FENÓMENOS Y PROCESOS::fenómenos fisiológicos oculares::presión intraocular</dc:subject>
   <dc:subject>TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::equipos y suministros::prótesis e implantes::implantes de drenaje del glaucoma</dc:subject>
   <dc:subject>TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::equipos y suministros::prótesis e implantes::stents</dc:subject>
   <dcterms:abstract>Glaucoma; Presión intraocular; Tratamiento quirúrgico</dcterms:abstract>
   <dcterms:abstract>Glaucoma; Pressió intraocular; Tractament quirúrgic</dcterms:abstract>
   <dcterms:abstract>Glaucoma; Intraocular pressure; Treatment surgery</dcterms:abstract>
   <dcterms:abstract>Background Different aqueous restrictive manoeuvres in non-valved devices affect intraocular pressure (IOP) levels in the first postoperative month. This study compares tube ligature (TL) alone to TL plus rip cord stent (TLS) on the efficacy of the Baerveldt 350.&#xd;
Methods We conducted a retrospective consecutive case-series observational study to assess efficacy by measuring IOP, success rates and the reduction of antiglaucoma medication usage over 3 years.&#xd;
Results The study included 43 eyes in the TL group and 29 in the TLS group. Initial IOPs were 26.67 mm Hg for TL and 28.21 mm Hg for TLS. After 1 year, IOP decreased to 13.03 mm Hg and 12.11 mm Hg, respectively. Over 3 years, TLS consistently achieved greater reductions in IOP compared with TL, with significant differences of 3.56 mm Hg in the second year (p=0.01) and 3.34 mm Hg in the third year (p=0.01). Mean antiglaucoma medication use decreased from 3.03 (SD 1.29) to 0.72 (SD 0.47) over 3 years, representing a 76.24% reduction, with no differences between the TL and TLS groups. Failure rate at 1 year was significantly lower for TLS under the success criteria of IOP=(6–18) mm Hg (TL: 33.33%, TLS: 7.14%, p=0.02). Rates of transient hypotension and hypertensive phase were higher in the TL group: 93.02% vs 34.48% (p&lt;0.001) and 58.14% vs 32.14% (χ²=4.59, p=0.03), respectively.&#xd;
Conclusion Adding the rip cord stent to the Baerveldt implant significantly enhances long-term IOP control and reduces failure rates compared with TL alone. The lower incidence of hypertensive phases could be due to sequential tube opening. Small sample size, lack of randomisation and follow-up discrepancies may introduce bias and limit statistical power, highlighting the need for further research to confirm these conclusions.</dcterms:abstract>
   <dcterms:dateAccepted>2025-10-24T10:37:54Z</dcterms:dateAccepted>
   <dcterms:available>2025-10-24T10:37:54Z</dcterms:available>
   <dcterms:created>2025-10-24T10:37:54Z</dcterms:created>
   <dcterms:issued>2025-04-11T11:58:26Z</dcterms:issued>
   <dcterms:issued>2025-04-11T11:58:26Z</dcterms:issued>
   <dcterms:issued>2025-02-13</dcterms:issued>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
   <dc:identifier>http://hdl.handle.net/11351/12943</dc:identifier>
   <dc:relation>BMJ Open Ophthalmology;10(1)</dc:relation>
   <dc:relation>https://doi.org/10.1136/bmjophth-2024-001879</dc:relation>
   <dc:rights>Attribution-NonCommercial 4.0 International</dc:rights>
   <dc:rights>http://creativecommons.org/licenses/by-nc/4.0/</dc:rights>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:publisher>BMJ</dc:publisher>
   <dc:source>Scientia</dc:source>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>