<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-14T03:05:46Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:10459.1/59869" metadataPrefix="mets">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:10459.1/59869</identifier><datestamp>2024-12-05T22:15:26Z</datestamp><setSpec>com_2072_3622</setSpec><setSpec>col_2072_479130</setSpec></header><metadata><mets xmlns="http://www.loc.gov/METS/" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" ID="&#xa;&#x9;&#x9;&#x9;&#x9;DSpace_ITEM_10459.1-59869" TYPE="DSpace ITEM" PROFILE="DSpace METS SIP Profile 1.0" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd" OBJID="&#xa;&#x9;&#x9;&#x9;&#x9;hdl:10459.1/59869">
   <metsHdr CREATEDATE="2026-04-14T05:05:46Z">
      <agent ROLE="CUSTODIAN" TYPE="ORGANIZATION">
         <name>RECERCAT</name>
      </agent>
   </metsHdr>
   <dmdSec ID="DMD_10459.1_59869">
      <mdWrap MDTYPE="MODS">
         <xmlData xmlns:mods="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
            <mods:mods xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Mehling, Harald</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Barreneche Güerisoli, Camila</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Solé, Aran</mods:namePart>
               </mods:name>
               <mods:name>
                  <mods:role>
                     <mods:roleTerm type="text">author</mods:roleTerm>
                  </mods:role>
                  <mods:namePart>Cabeza, Luisa F.</mods:namePart>
               </mods:name>
               <mods:extension>
                  <mods:dateAccessioned encoding="iso8601">2024-12-05T22:15:26Z</mods:dateAccessioned>
               </mods:extension>
               <mods:extension>
                  <mods:dateAvailable encoding="iso8601">2024-12-05T22:15:26Z</mods:dateAvailable>
               </mods:extension>
               <mods:originInfo>
                  <mods:dateIssued encoding="iso8601">2017-06-15T08:38:22Z2019-12-31T23:14:38Z20172017-06-15T08:38:23Z</mods:dateIssued>
               </mods:originInfo>
               <mods:identifier type="none"/>
               <mods:identifier type="uri">http://hdl.handle.net/10459.1/59869</mods:identifier>
               <mods:abstract>Using phase change materials (PCM) for Thermal Energy Storage, the most important material property is their heat storage capability, usually given as h(T). Ideally, h(T) changes suddenly at a single temperature. However, many PCM change phase in a temperature range and show hysteresis. In addition, experience shows that even measurements with the same device on the same material can give different results when the heating rate, the amount of sample mass or the equipment device are varied. The question thus arises how to deal with different h(T) results when trying to predict the performance of a real scale application. This paper identifies the main origins of these effects and gives strategies for dealing with them.The research leading to these results has received funding from the European Commission&#xd;
Seventh Framework Programme (FP/2007-2013) under grant agreement n° PIRSES-GA-2013-610692 (INNOSTORAGE) and from the European Union’s Horizon 2020 research and&#xd;
innovation program under grant agreement No 657466 (INPATH-TES). The authors would like&#xd;
to thank the Catalan Government for the quality accreditation given to their research groups&#xd;
GREA (2014 SGR 123) and DIOPMA (2014 SGR 1543). GREA and DIOPMA are certified&#xd;
agents TECNIO in the category of technology developers from the Government of Catalonia.&#xd;
This work has been partially funded by the Spanish government (ENE2015-64117-C5-1-R&#xd;
(MINECO/FEDER)). Dr. Camila Barreneche and Dr. Aran Solé would like to thank Ministerio&#xd;
de Economía y Competitividad de España for Grant Juan de la Cierva, FJCI-2014-22886 and&#xd;
FJCI-2015-25741, respectively.</mods:abstract>
               <mods:language>
                  <mods:languageTerm authority="rfc3066"/>
               </mods:language>
               <mods:accessCondition type="useAndReproduction">cc-by-nc-nd (c) Elsevier, 2017 info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by-nc-nd/4.0/</mods:accessCondition>
               <mods:subject>
                  <mods:topic>Phase Change Material (PCM)</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Material property</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Latent heat</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Heat capacity</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Enthalpy</mods:topic>
               </mods:subject>
               <mods:subject>
                  <mods:topic>Hysteresis</mods:topic>
               </mods:subject>
               <mods:titleInfo>
                  <mods:title>The connection between the heat storage capability of PCM as a material property and their performance in real scale applications</mods:title>
               </mods:titleInfo>
               <mods:genre>info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion</mods:genre>
            </mods:mods>
         </xmlData>
      </mdWrap>
   </dmdSec>
   <structMap LABEL="DSpace Object" TYPE="LOGICAL">
      <div TYPE="DSpace Object Contents" ADMID="DMD_10459.1_59869"/>
   </structMap>
</mets></metadata></record></GetRecord></OAI-PMH>