<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-17T14:57:49Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:10459.1/47788" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:10459.1/47788</identifier><datestamp>2024-12-05T22:53:53Z</datestamp><setSpec>com_2072_3622</setSpec><setSpec>col_2072_479130</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Life Cycle Assessment of the inclusion of phase change materials (PCM) in experimental buildings</dc:title>
   <dc:creator>Gracia Cuesta, Alvaro de</dc:creator>
   <dc:creator>Castell, Albert</dc:creator>
   <dc:creator>Jiménez, Melanie</dc:creator>
   <dc:creator>Boer, Dieter</dc:creator>
   <dc:creator>Medrano Martorell, Marc</dc:creator>
   <dc:creator>Cabeza, Luisa F.</dc:creator>
   <dc:creator>Rincón, Lídia</dc:creator>
   <dc:subject>LCA</dc:subject>
   <dc:subject>PCM</dc:subject>
   <dc:subject>TES</dc:subject>
   <dcterms:abstract>The present work evaluates the environmental impact of including phase change materials (PCM) in a&#xd;
typical Mediterranean building. A Life Cycle Assessment (LCA) is developed for three monitored cubicles&#xd;
built in Puigverd de Lleida (Spain). It is possible to control the inner temperature of the cubicles using&#xd;
a domestic heat pump for cooling and an electrical radiator for heating: The energy consumption is&#xd;
registered to determine the energy savings achieved. The aim is to analyze if these energy savings are&#xd;
large enough to balance the environmental impact originated during the manufacturing of PCM.&#xd;
Some hypothetical scenarios, such as different systems to control the temperature different PCM types&#xd;
or different weather conditions are proposed and studied using LCA process to point out the critical issues.&#xd;
Furthermore, a parametric analysis of the lifetime of buildings is developed.&#xd;
Results show that the addition of PCM in the building envelope, although decreasing the energy consumption&#xd;
during operation, does not reduce significantly the global impact throughout the lifetime of&#xd;
the building. For the hypothetical scenario considering summer conditions all year around and a lifetime&#xd;
of the building of 100 years, the use of PCM reduces the overall impact by more than 10%.</dcterms:abstract>
   <dcterms:abstract>The work was partially funded by the Spanish government&#xd;
(projects ENE2008-06687-C02-01/CON, CTQ2009-14420-C02 and&#xd;
DPI2008-04099I) and the European Union (COST Action COST&#xd;
TU0802), in collaboration with the companies Synthesia, Honeywell,&#xd;
and Cityhall of Puigverd de Lleida. The authors would&#xd;
like to thank the Catalan Government for the quality accreditation&#xd;
given to their research group (2009 SGR 534). The authors&#xd;
also wish to acknowledge support of this research work from the&#xd;
Spanish Ministry of Education and Science (DPI2008-04099/DPI&#xd;
and CTQ2009-14420) and the Spanish Ministry of External Affairs&#xd;
(A/023551/09).</dcterms:abstract>
   <dcterms:dateAccepted>2024-12-05T22:53:52Z</dcterms:dateAccepted>
   <dcterms:available>2024-12-05T22:53:52Z</dcterms:available>
   <dcterms:created>2024-12-05T22:53:52Z</dcterms:created>
   <dcterms:issued>2015-02-02T10:51:02Z</dcterms:issued>
   <dcterms:issued>2025-01-01</dcterms:issued>
   <dcterms:issued>2010</dcterms:issued>
   <dc:type>article</dc:type>
   <dc:type>publishedVersion</dc:type>
   <dc:identifier>http://hdl.handle.net/10459.1/47788</dc:identifier>
   <dc:relation>MICINN/PN2008-2011/ENE2008-06687-C02-01/CON</dc:relation>
   <dc:relation>MICINN/PN2008-2011/CTQ2009-14420-C02</dc:relation>
   <dc:relation>MICINN/PN2008-2011/DPI2008-04099I</dc:relation>
   <dc:relation>Reproducció del document publicat a https://doi.org/10.1016/j.enbuild.2010.03.022</dc:relation>
   <dc:relation>Energy and Buildings, 2010, núm. 42, p. 1517–1523</dc:relation>
   <dc:rights>(c) Elsevier, 2010</dc:rights>
   <dc:rights>info:eu-repo/semantics/restrictedAccess</dc:rights>
   <dc:publisher>Elsevier</dc:publisher>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>