<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-13T02:11:13Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:10459.1/468963" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:10459.1/468963</identifier><datestamp>2025-11-17T19:06:09Z</datestamp><setSpec>com_2072_3622</setSpec><setSpec>col_2072_479130</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Comparative evaluation of UV-HPLC methods and reducing agents to determine vitamin C in fruits</dc:title>
   <dc:creator>Odriozola Serrano, Isabel</dc:creator>
   <dc:creator>Hernández-Jover, Teresa</dc:creator>
   <dc:creator>Martín Belloso, Olga</dc:creator>
   <dc:subject>Ascorbic acid</dc:subject>
   <dc:subject>Vitamin C</dc:subject>
   <dc:subject>Fruits Reliability</dc:subject>
   <dc:subject>Comparison</dc:subject>
   <dcterms:abstract>Vitamin C is one of the most important antioxidant supplied by fruits and vegetables. Therefore a reliable and easy method is needed for its determination. In this work, two UV-HPLC methods for the determination of ascorbic acid were validated and compared in strawberries, tomatoes and apples. In addition, two different reducing agents [dl-1,4-dithiotreitol (DTT) or 2,3-dimercapto-1-propanol (BAL)] were tried for differentiate dehydroascorbic acid and determine vitamin C. Reliability resulted satisfactory for the UV-HPLC methods in each fruit. UV-HPLC methods resulted linear up to 5 mg/100 g and the least detection and quantification limits were &lt;0.18 mg/100 g and &lt;0.61 mg/100 g, respectively. Precision, as relative standard deviation, ranged from 0.6% to 3.9% and the recovery between 93.6% and 104.4%. Although, the UV-HPLC methods resulted useful for the routine analysis of AA and vitamin C in fruits, the best reliability was achieved when using a C18 column and DTT as reducing agent. Moreover, it may be the UV-HPLC method of choice because it is the easiest and cheapest to perform.</dcterms:abstract>
   <dcterms:issued>2007</dcterms:issued>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:type>info:eu-repo/semantics/acceptedVersion</dc:type>
   <dc:relation>Reproducció del document publicat a https://doi.org/10.1016/j.foodchem.2007.02.037</dc:relation>
   <dc:relation>Food Chemistry, 2007, vol. 105, núm. 3, p. 1151-1158</dc:relation>
   <dc:rights>cc-by-nc-nd (c) Elsevier, 2007</dc:rights>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:publisher>Elsevier</dc:publisher>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>