<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-17T03:43:07Z</responseDate><request verb="GetRecord" identifier="oai:www.recercat.cat:10256/12132" metadataPrefix="qdc">https://recercat.cat/oai/request</request><GetRecord><record><header><identifier>oai:recercat.cat:10256/12132</identifier><datestamp>2024-05-22T09:48:56Z</datestamp><setSpec>com_2072_452955</setSpec><setSpec>com_2072_2054</setSpec><setSpec>col_2072_452957</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Accurate display gamma functions based on human observation</dc:title>
   <dc:creator>Neumann, Attila</dc:creator>
   <dc:creator>Artusi, Alessandro</dc:creator>
   <dc:creator>Neumann, László</dc:creator>
   <dc:creator>Zotti, Georg</dc:creator>
   <dc:creator>Purgathofer, Werner</dc:creator>
   <dc:subject>Visualització (Informàtica)</dc:subject>
   <dc:subject>Information display systems</dc:subject>
   <dc:subject>Terminals de pantalla de visualització</dc:subject>
   <dc:subject>Video display terminals</dc:subject>
   <dcterms:abstract>This article describes an accurate method to obtain the tone reproduction curve of display devices without using a measurement device. It is an improvement of an existing technique based on human observation, solving its problem of numerical instability and resulting in functions in log - log scale which correspond better to the nature of display devices. We demonstrate the efficiency of our technique on different monitor technologies, comparing it with direct measurements using a spectrophotometer</dcterms:abstract>
   <dcterms:abstract>Contract grant sponsor: European Union (Real Reflect Project); Contract grant number: IST-2001-34744. Contract grant sponsor: Spanish Government; Contract grant number: TIC2001-2416-C03-01. Contract grant sponsor: Research Promotion Foundation (Cyprus IPE Project); Contract grant number: PLHRO/1104/21</dcterms:abstract>
   <dcterms:dateAccepted>2024-05-22T09:48:55Z</dcterms:dateAccepted>
   <dcterms:available>2024-05-22T09:48:55Z</dcterms:available>
   <dcterms:created>2024-05-22T09:48:55Z</dcterms:created>
   <dcterms:issued>info:eu-repo/date/embargoEnd/2026-01-01</dcterms:issued>
   <dcterms:issued>info:eu-repo/date/embargoEnd/2026-01-01</dcterms:issued>
   <dcterms:issued>2007</dcterms:issued>
   <dc:type>info:eu-repo/semantics/article</dc:type>
   <dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
   <dc:identifier>http://hdl.handle.net/10256/12132</dc:identifier>
   <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1002/col.20336</dc:relation>
   <dc:relation>info:eu-repo/semantics/altIdentifier/issn/0361-2317</dc:relation>
   <dc:relation>info:eu-repo/semantics/altIdentifier/eissn/1520-6378</dc:relation>
   <dc:relation>MICYT/PN 2001-2004/TIC2001-2416-C03-01</dc:relation>
   <dc:rights>Tots els drets reservats</dc:rights>
   <dc:rights>info:eu-repo/semantics/embargoedAccess</dc:rights>
   <dc:publisher>Wiley</dc:publisher>
   <dc:source>© Color Research and Application, 2007, vol. 32, núm. 4, p. 310-319</dc:source>
   <dc:source>Articles publicats (D-ATC)</dc:source>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>