dc.contributor |
Université de Québec. École de technologie supérieure |
dc.contributor |
Belanger, Pierre |
dc.contributor.author |
Ortiz Alcalá, Lluís |
dc.date |
2013 |
dc.identifier.uri |
http://hdl.handle.net/2099.1/24953 |
dc.language.iso |
eng |
dc.publisher |
Universitat Politècnica de Catalunya |
dc.publisher |
Université du Québec - École de Technologie Supérieure |
dc.rights |
Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights |
info:eu-repo/semantics/openAccess |
dc.rights |
http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject |
Àrees temàtiques de la UPC::Enginyeria civil::Enginyeria hidràulica, marítima i sanitària::Enginyeria sanitària |
dc.subject |
Àrees temàtiques de la UPC::Informàtica::Programació |
dc.subject |
Àrees temàtiques de la UPC::Matemàtiques i estadística::Anàlisi numèrica::Modelització matemàtica |
dc.subject |
Pipelines -- Maintenance and repair -- Computer simulation |
dc.subject |
Ultrasonic testing |
dc.subject |
ANSYS (Computer system |
dc.subject |
Abaqus (Electronic resource) |
dc.subject |
Canonades -- Manteniment i reparació -- Simulació per ordinador |
dc.subject |
Ultrasons -- Proves |
dc.subject |
ANSYS (Sistema informàtic) |
dc.subject |
ABAQUS (programes d'ordinadors) |
dc.title |
Comparison Between Ansys And Abaqus Using Ultrasonic Guided Waves |
dc.type |
info:eu-repo/semantics/bachelorThesis |
dc.description.abstract |
The detection of corrosion in pipelines is an aspect of utmost importance as far as
the fluid transportation industry is concerned, and especially if they have a difficult
access. As they are installed outdoors or underground, these kilometric conduits are
under various weather and natural phenomena, which may damage them causing
loses and consequently serious natural disasters.
Over the years, the most common way to check the pipelines’ thickness has been
thanks to ultrasonic and Foucault currents. The constraint of these techniques is that
they only allow examining the thickness just under the probe. Thus, the checking
procedure along its entire length becomes a very dull and long process. The problem
arises when the access to certain stretches of those pipelines becomes extremely
complex, making this control impossible. Upon needing to inspect these pipelines in
a precise, quickly and easy way along their length, this control method is rarely used
any more.
Low frequency guided waves are beginning to be used frequently to perform this task
since their detection and location capability of corroded patches is very good. The
only drawback that this screening technique presents is that it only gives a rough
estimate of the remaining wall thickness. Currently, guided waves are the most
powerful method not only to detect inaccessible corroded patches but also to map
their remaining thickness precisely.
Nowadays, the world of computer science is so immensely vast that there is a large
amount of software solutions to perform the same task. The problem ascends when
a user needs to complete a specific job and does not know which of the programs at
his disposal to choose. Some of the aspects that will prevail in his decision is if the
software’s interface is good-looking, the price of software’s license, the memory
consumption at the time of performing a task but mainly the time taken to complete
the work.
The aim of this report is to compare two of the most important programs for finite
elements simulations: Abaqus and ANSYS. This analysis was done by applying a
signal of 50 kHz and 10 cycles, involved in a Hanning window in a titanium plate of 1
m long and with a thickness of 5 mm. The reason why this study was done by
simulating a plate instead of a pipeline, without forgetting the aforementioned, is
because it was needed to simulate an easy geometry in order to shorten the time
taken to solve the simulation by both software solutions. The conclusions of this work were obtained by analysing which of the software
solutions offered the most accurate displacements of a node located one meter far
from where the signal was implemented. In case that both were equally precise, what
was determinant for us at the time of choosing the best software program was which
of both took the highest analysis speed, less time and memory consumption to
perform the task. |
dc.description.abstract |
Outgoing |