Para acceder a los documentos con el texto completo, por favor, siga el siguiente enlace: http://hdl.handle.net/2117/25473

Optical quality and intraocular scattering assessed with a double-pass system in eyes with contact lens induced corneal swelling
De Juan, Victoria; Aldaba Arévalo, Mikel; Martin, Raul; Vilaseca Ricart, Meritxell; Herrera, Jose Maria; Pujol Ramo, Jaume
Universitat Politècnica de Catalunya. Departament d'Òptica i Optometria; Universitat Politècnica de Catalunya. GREO - Grup de Recerca en Enginyeria Òptica
Purpose: To evaluate the impact of contact lens (CL)-induced corneal swelling on the optical quality of the eye by means of the double-pass technique.; Methods: Measurements of 6 healthy subjects were obtained in 5 visits over 1 week, at baseline and after sleeping with 4 different CLs of +0.50 D, +2.00 D, +5.00 D and +8.00 D (Acuvue2), randomly fitted on 4 different days. The control eye wore no CL Corneal pachymetry and optical quality of the eye (OQAS, Visiometrics) were measured once at baseline and at three interval times in the follow-up.visits: immediately after CL removal, and 1 and 2 h after CL removal. Optical quality was evaluated by means of the Strehl ratio and OQAS values at 100%, 20% and 9% contrasts. Intraocular scattering was evaluated with the objective scatter index (OSI).; Results: Mean overnight swelling was 5.98 4.29% in CL-eyes versus 0.30 0.78% in control eyes (p <0.01). Corneal swelling was maximal immediately after CL removal and decreased with time (p <0.01). A significant worsening in all optical quality parameters and a significant increase of the OSI were found in eyes with corneal swelling (p < 0.05). Two hours after CL removal there were no statistically significant differences (p >0.05) between CL-eyes and control eyes in any of the measured parameters.; Conclusions: Corneal swelling has a significant impact on the optical quality of the eye and on intraocular scattering as assessed with the double-pass technique. (C) 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Àrees temàtiques de la UPC::Ciències de la visió::Contactologia
Contact lenses
Cornea
Eye--Accommodation and refraction
Edema
Contact lens
Overnight
Contact swelling
Optical quality
Scattering
RETINAL IMAGE QUALITY
COHERENCE TOMOGRAPHY
EXTENDED WEAR
THICKNESS
PERFORMANCE
INSTRUMENT
Lents de contacte
Còrnia
Ulls -- Acomodació i refracció
Attribution-NonCommercial-NoDerivs 3.0 Spain
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
info:eu-repo/semantics/publishedVersion
Artículo
         

Mostrar el registro completo del ítem

Documentos relacionados

Otros documentos del mismo autor/a

Vilaseca Ricart, Meritxell; Díaz-Doutón, Fernando; Luque, Sergio Oscar; Aldaba Arévalo, Mikel; Arjona Carbonell, Mª Montserrat; Pujol Ramo, Jaume
Aldaba Arévalo, Mikel; Vilaseca Ricart, Meritxell; Díaz-Doutón, Fernando; Arjona Carbonell, Mª Montserrat; Pujol Ramo, Jaume
Aldaba Arévalo, Mikel; Vilaseca Ricart, Meritxell; Arjona Carbonell, Mª Montserrat; Pujol Ramo, Jaume
Giner Tort, Anna; Aldaba Arévalo, Mikel; Arjona Carbonell, Mª Montserrat; Vilaseca Ricart, Meritxell; Pujol Ramo, Jaume
Aldaba Arévalo, Mikel; Gómez López, Selena; Vilaseca Ricart, Meritxell; Pujol Ramo, Jaume; Arjona Carbonell, Mª Montserrat