Para acceder a los documentos con el texto completo, por favor, siga el siguiente enlace: http://hdl.handle.net/2117/18535

In silico evaluation of a new composite disc substitute with a L3-L5 lumbar spine finite element model
Noailly, Jérôme; Ambrosio, Luigi; Tanner, K. Elizabeth; Planell Estany, Josep Anton; Lacroix, Damien Jerome
Universitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica; Universitat Politècnica de Catalunya. BBT - Biomaterials, Biomecànica i Enginyeria de Teixits
When the intervertebral disc is removed to relieve chronic pain, subsequent segment stabilization should restore the functional mechanics of the native disc. Because of partially constrained motions and the lack of intrinsic rotational stiffness ball-on-socket implants present many disadvantages. Composite disc substitutes mimicking healthy disc structures should be able to assume the role expected for a disc substitute with fewer restrictions than ball-on-socket implants. A biomimetic composite disc prototype including artificial nucleus fibre-reinforced annulus and endplates was modelled as an L4–L5 disc substitute within a L3–L5 lumbar spine finite element model. Different device updates, i.e. changes of material properties fibre distributions and volume fractions and nucleus placements were proposed. Load- and displace- ment-controlled rotations were simulated with and without body weight applied. The original prototype reduced greatly the flexibility of the treated segment with signifi- cant adjacent level effects under displacement-controlled or hybrid rotations. Device updates allowed restoring large part of the global axial and sagittal rotational flexibility predicted with the intact model. Material properties played a major role, but some other updates were identified to potentially tune the device behaviour against specific motions. All device versions altered the coupled interseg- mental shear deformations affecting facet joint contact through contact area displacements. Loads in the bony endplates adjacent to the implants increased as the implant stiffness decreased but did not appear to be a strong limi- tation for the implant biomechanical and mechanobiolog- ical functionality. In conclusion, numerical results given by biomimetic composite disc substitutes were encouraging with greater potential than that offered by ball-on-socket implants
Peer Reviewed
-Àrees temàtiques de la UPC::Enginyeria dels materials
-Lumbar vertebrae
-Finite element method
-Elements finits, Mètode dels
-Vèrtebres lumbars
Attribution-NonCommercial-NoDerivs 3.0 Spain
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
Artículo - Versión publicada
Artículo
         

Mostrar el registro completo del ítem

Documentos relacionados

Otros documentos del mismo autor/a

Noailly, Jérôme; Planell Estany, Josep Anton; Lacroix, Damien Jerome
Dessi, Mariagemiliana; Alvarez Perez, Marco Antonio; De Santis, Roberto; Ginebra Molins, Maria Pau; Planell Estany, Josep Anton; Ambrosio, Luigi
Montufar Jiménez, Edgar Benjamin; Traykova, Tania; Schacht, Etienne; Ambrosio, Luigi; Santin, Matteo; Planell Estany, Josep Anton; Ginebra Molins, Maria Pau
Malandrino, Andrea; Fritsch, Andreas; Lahayne, Olaf; Kropik, Karl; Redl, Heinz; Noailly, Jérôme; Lacroix, Damien Jerome; Hellmich, Christian