Validation of an automatic dose injection system for Ictal SPECT in epilepsy
Setoain Perego, Xavier; Pavía Segura, Javier; Serés, Eulàlia; Garcia, Ramiro; Carreño, Maria Mar; Donaire, Antonio; Rubí, Sebastià; Bargalló Alabart, Nuria; Rumià, Jordi; Boget Llucià, Teresa; Pintor, Luis; Fuster, David; Pons Pons, Francisca
Universitat de Barcelona
The purpose of our study was to evaluate the performance and clinical usefulness of an automated injector system (AIS) that administers an automated injection for ictal SPECT after calculating the volume of tracer to be injected over time. Methods: To test the AIS, repeated injections were performed at different times after tracer preparation. The clinical study consisted of 56 patients with drug-resistant, complex partial seizures. Tracer for ictal SPECT was injected using automated injection in 27 patients and manual injection (MI) in the remaining 29. Injection time (TI) was measured in seconds from seizure onset to the end of volume injection. The SISCOM (Subtraction Ictal Spect Co-registered to MRI) procedure was used to locate the epileptogenic seizure focus with SPECT. The definition of seizure focus was made by consensus of the epilepsy unit using conventional diagnostic methods. Results: During the experimental phase, there were no system failures, and the error in injected doses when using automated injection was lower than with MI. During the clinical phase, TI using manual injection was 41 s with a range of 14-103 s, compared with an AIS average of 33 s with a range of 19-63 s (P , 0.05). Ictal SPECT and SISCOM successfully localized the seizure focus in 21 of the 27 patients (78%) by AIS and in 19 of the 29 patients (65%) by MI (P 5 0.14). Furthermore, nursing staff found the AIS method more convenient than the MI method. Conclusion: An AIS can improve the quality of work of the nursing staff in the neurology ward and allow a finer adjustment of the injection dose. Early results using an AIS would indicate a reduction in injection time and improved SPECT accuracy.
Assaigs clínics
Epilèpsia
Radiació
Tomografia computada per emissió de fotó simple
Neurologia
Clinical trials
Epilepsy
Radiation
Single-photon emission computed tomography
Neurology
(c) The Society of Nuclear Medicine and Molecular Imaging, 2012
Artículo
info:eu-repo/semantics/publishedVersion
The Society of Nuclear Medicine and Molecular Imaging
         

Mostrar el registro completo del ítem

Documentos relacionados

Otros documentos del mismo autor/a

Perissinotti, Andrés; Setoain Perego, Xavier; Aparicio, Javier; Rubí Sureda, Sebastià; Marti Fuster, Berta; Donaire, Antonio; Carreño, Mar Bargalló, N; Bargalló, Núria; Rumià, Jordi; Garcia-Fructuoso, Gemma; Mayoral, Maria; Sanmartí, Francesc; Pons Pons, Francisca
Peña-Gómez, Cleofé; Solé Padullés, Cristina; Clemente, Immaculada; Junqué i Plaja, Carme, 1955-; Bargalló Alabart, Nuria; Bosch Capdevila, Beatriz; Molinuevo, José L.; Valls Solé, Josep; Pascual Leone, Álvaro (Neuròleg); Bartrés Faz, David
Bullich Roig, Santiago; Ros Puig, Domènec; Cot Sanz, Albert; Falcón, C.; Muxí Pradas, África; Pavía Segura, Javier
Sampedro, Frederic; Vilaplana, Eduard; de Leon, Mony J.; Alcolea, Daniel; Pegueroles, Jordi; Montal, Victor; Carmona-Iragui, María; Sala, Isabel; Sanchez-Saudinos, María Belén; Antón-Aguirre, Sofía; Morenas-Rodriguez, Estrella; Camacho, Valle; Falcon, Carles; Pavía Segura, Javier; Ros Puig, Domènec; Clarimon, Jordi; Blesa, Rafael; Lleo, Alberto; Fortea, Juan; Alzheimer's Disease Neuroimaging Initiative
Peris Bernal, Pilar; Guañabens Gay, Núria; Pons Pons, Francisca; Herranz, R.; Monegal Brancós, Ana; Suris, X.; Muñoz Gómez, José