Validation of an automatic dose injection system for Ictal SPECT in epilepsy
Setoain Perego, Xavier; Pavía Segura, Javier; Serés, Eulàlia; Garcia, Ramiro; Carreño, Mar; Donaire, Antonio; Rubí, Sebastià; Bargalló Alabart, Núria​; Rumià, Jordi; Boget Llucià, Teresa; Pintor Pérez, Luis; Fuster, David; Pons Pons, Francisca
Universitat de Barcelona
The purpose of our study was to evaluate the performance and clinical usefulness of an automated injector system (AIS) that administers an automated injection for ictal SPECT after calculating the volume of tracer to be injected over time. Methods: To test the AIS, repeated injections were performed at different times after tracer preparation. The clinical study consisted of 56 patients with drug-resistant, complex partial seizures. Tracer for ictal SPECT was injected using automated injection in 27 patients and manual injection (MI) in the remaining 29. Injection time (TI) was measured in seconds from seizure onset to the end of volume injection. The SISCOM (Subtraction Ictal Spect Co-registered to MRI) procedure was used to locate the epileptogenic seizure focus with SPECT. The definition of seizure focus was made by consensus of the epilepsy unit using conventional diagnostic methods. Results: During the experimental phase, there were no system failures, and the error in injected doses when using automated injection was lower than with MI. During the clinical phase, TI using manual injection was 41 s with a range of 14-103 s, compared with an AIS average of 33 s with a range of 19-63 s (P , 0.05). Ictal SPECT and SISCOM successfully localized the seizure focus in 21 of the 27 patients (78%) by AIS and in 19 of the 29 patients (65%) by MI (P 5 0.14). Furthermore, nursing staff found the AIS method more convenient than the MI method. Conclusion: An AIS can improve the quality of work of the nursing staff in the neurology ward and allow a finer adjustment of the injection dose. Early results using an AIS would indicate a reduction in injection time and improved SPECT accuracy.
-Assaigs clínics
-Epilèpsia
-Radiació
-Tomografia computada per emissió de fotó simple
-Neurologia
-Clinical trials
-Epilepsy
-Radiation
-Single-photon emission computed tomography
-Neurology
(c) The Society of Nuclear Medicine and Molecular Imaging, 2012
Article
Article - Published version
The Society of Nuclear Medicine and Molecular Imaging
         

Show full item record

Related documents

Other documents of the same author

Carreño, Mar; Bien, Christian; Asadi-Pooya, Ali A.; Sperling, Michael; Marusic, Petr; Elisak, Martin; Pimentel, Jose; Wehner, Tim; Mohanraj, Rajiv; Uranga, Juan; Gómez-Ibáñez, Asier; Villanueva, Vicente; Gil López, Francisco; Donaire, Antonio; Bargalló Alabart, Núria​; Rumià, Jordi; Roldán, Pedro; Setoain Perego, Xavier; Pintor Pérez, Luis; Boget Llucià, Teresa; Bailles, Eva; Falip, Mercè; Aparicio, Javier; Dalmau Obrador, Josep; Graus Ribas, Francesc
Perissinotti, Andrés; Setoain Perego, Xavier; Aparicio, Javier; Rubí Sureda, Sebastià; Marti Fuster, Berta; Donaire, Antonio; Carreño, Mar; Bargalló Alabart, Núria​; Rumià, Jordi; Garcia-Fructuoso, Gemma; Mayoral, Maria; Sanmartí, Francesc; Pons Pons, Francisca
Iurina, Elena; Baillès, Eva; Carreño, Mar; Donaire, Antonio; Rumià, Jordi; Boget, Teresa; Bargalló, Núria; Setoain, Xavier; Roldan, Pedro; Conde-Blanco, Estefanía; Centeno, Maria; Pintor, Luis.
Salazar Garcia, Fátima; Doñate, Marta; Boget Llucià, Teresa; Bogdanovich, Ana; Basora Macaya, Misericordia; Torres, Ferran; Gracia, Isabel; Fàbregas Julià, Neus
Salazar Garcia, Fátima; Doñate, Marta; Boget Llucià, Teresa; Bogdanovich, Ana; Basora Macaya, Misericordia; Torres, Ferran; Gracia, Isabel; Fàbregas Julià, Neus
 

Coordination

 

Supporters