The study of mechanomyographic (MMG) signals
of respiratory muscles is a promising technique in order to evaluate the respiratory muscular effort. In this work MMG
signals from left and right hemidiaphragm (MMGl and MMGr, respectively) acquired during a respiratory protocol have been analyzed. The acquisition of both MMG signals was carried out by means of two capacitive accelerometers placed on both left and right sides of the costal wall. The signals were recorded in a group of six patients with Chronic Obstructive
Pulmonary Disease (COPD). It has been observed that with the increase of inspiratory pressure it takes place an increase of the amplitude and a displacement toward low frequencies in both left and right MMG signals. Furthermore, it has been seen that the increase of amplitude and the decrease of frequency in MMG signals are more pronounced in severe COPD patients.
This behaviour is similar for both MMGl and MMGr signals.
Results suggest that the use of MMG signals could be potentially useful for the evaluation of the respiratory muscular function in COPD patients. |