Título:
|
A study of etching conditions and resolution power of plastic detector CR-39
|
Autor/a:
|
Domingo Miralles, Carles; Ortega Girón, Manuel; Fernández Moreno, Francisco; Vidal-Quadras Roca, Alejo; Font García, Josep Lluís; Baixeras Divar, Carmen; Casas Ametller, Montserrat
|
Otros autores:
|
Universitat Politècnica de Catalunya. Departament de Física i Enginyeria Nuclear; Universitat Politècnica de Catalunya. DONLL - Dinàmica no Lineal, Òptica no Lineal i Làsers |
Abstract:
|
Two Pershore Stacks (32 h cure cycle and 1% DOP and 96 h cure cycle and no additive) have been exposed to the Berkeley Bevalac Argon beam at 285 MeV/nuc and 425 MeV/nuc, respectively. Optimum previous termetching conditionsnext term have been found to be 70°C temperature and 18 h previous termetchingnext term time in 6.25 N OHNa aquaeous solution, corresponding to a mean bulk etch rate VB = (1.37±0.09) μm/h. The charge and mass previous termresolutionnext term power of the detector has been evaluated as ΔZ ≈ 0.3 e and ΔA ≈ 2 a.m.u.. |
Abstract:
|
Peer Reviewed |
Materia(s):
|
-Àrees temàtiques de la UPC::Física::Física de partícules -Nuclear track detectors -Polymers -Traça nuclear -- Detectors -Polímers |
Derechos:
|
|
Tipo de documento:
|
Artículo - Versión presentada Artículo |
Editor:
|
Pergamon Press
|
Compartir:
|
|